Appendix A
Memory Upgrade Instructions for Firepower Management Centers
Step 2
Locate the DIMMs on the system board. See
your FireSIGHT Management Center model, for the location of the DIMM connectors.
Step 3
Pull the latches away from the DIMM at both ends; this lifts the DIMM slightly. Then lift the DIMM out
of the connector. See
Figure A-12
1
What to Do Next:
Installing DIMMs in Firepower Management Centers
To install a DIMM in a Firepower MC750 (Rev. 1 and 2), MC1500, and MC3500:
Step 1
Locate the DIMMs on the system board:
Step 2
Make sure that both latches on the DIMM connector are in the open position.
Step 3
Orient the DIMM so that the polarization notch lines up with the polarization key on the connector. See
Figure
Step 4
Align the DIMM carefully into the connector.
Step 5
Carefully and firmly press the DIMM into the connector until the latches close onto the DIMM. Make
sure that both latches rotate to the closed position against the DIMM. See
Figure
A-12.
Removing a DIMM
1
Open the latches
Place any removed DIMMs in anti-static bags to protect them from ESD damage. Observe
applicable Federal, state, and local regulations regarding the disposal of these components.
Install the new DIMMs from your memory upgrade kit in your FireSIGHT Management Center as
described in the
"Installing DIMMs in Firepower Management Centers" section on page
Refer to
Figure A-9
for the location of the DIMM connectors on the MC750 (Rev. 1).
Refer to
Figure A-10
for the location of the DIMM connectors on the MC750 (Rev. 2).
Refer to
Figure A-11
for the location of the DIMM connectors on the MC1500 and MC3500.
Refer to
Table A-3
for memory upgrade configurations for each Management Center model.
A-8.
Cisco Firepower Management Center 750, 1500, 2000, 3500, and 4000 Hardware Installation Guide
Figure
A-9,
Figure
A-10, or
2
2
Lift DIMM out
Replacing the DIMMs
Figure A-11
depending on
1
A-13.
Figure
A-13.
A-13