System Installation:
Preparation:
Check the following components to ensure that all parts are packed with your system:
1 – Storage Tank
1 – Reverse Osmosis System
1 – Tubing Accessories
Determine the location for the installation of the RO system. Avoid locations where the system
might come in contact with hot water and other hazards. Make sure that a drain location is
provided for the RO system. An air gap is required to ensure that contamination is avoided from
other water sources. Determine the location of the storage tank. A maximum distance from RO
system to tank is 4.5 meters (15 feet).
All inlets and outlets are individually labeled for ease of installation:
(1/4") FEED – Connects the feed water supply to the inlet of the sediment filter.
(1/4") DRAIN – Connect the membrane brine port to drain.
(3/8") TANK – Connect the membrane pure water port to storage tank.
(3/8") SAMPLE – Connects the storage tank to the Gemini or Aries High Purity system inlet
(3/8") OUTLET – Any additional outlets for RO water.
Fittings and Tubing:
Quick disconnect fittings are used throughout the system. To ensure an optimal seal, tubing
should be cut with the end square. An angled cut or distortion of the tubing will not provide an
efficient seal and may cause leaks.
To install a tube, push in the collet until it seats firmly. To remove a tube, push in the collet and
pull out the tube.
Secure connections are simple:
1) Cut the tube square and push past the O-ring to the tube stop
2) Tube is secured in position
3) Disconnection is just as easy
Push collet against body
Slide tube out of fitting
M-0221201113
Page 3 of 7
Revision 4