Aeotec ZWA005 Manuale - Pagina 3
Sfoglia online o scarica il pdf Manuale per Accessories Aeotec ZWA005. Aeotec ZWA005 8. Trisensor

1)
Motion Retrigger Time
This parameter is configured the delay time before PIR sensor can be triggered again to
reset motion timeout counter. Value = 0 will disable PIR sensor from triggering until motion
timeout has finished.
Parameter Number
1
2)
Motion Clear Time
This parameter is configured the time to clear motion event after a motion event detected.
Time to motion clear, the device will send a clear event report to controller and send BASIC_SET
= 0x00 to nodes associated in group 2. Unit: Second.
Parameter Number
2
3)
Motion Sensitivity
This parameter is configured the sensitivity that motion detect.
0 – PIR sensor disabled.
1 – Lowest sensitivity.
11 – Highest sensitivity.
Parameter Number
3
4)
Binary Sensor Report Enable
'0' –Disable sensor binary report when motion event is detected or cleared.
'1' –Enable sensor binary report when motion event is detected or cleared.
Parameter Number
4
5)
Disable BASIC_SET to Associated nodes
This parameter is configured the enabled or disabled send BASIC_SET command to nodes
that associated in group 2 and group 3.
0 – Disabled All Group Basic Set Command
1 – Enabled Group 2 Basic Set Command, Group 3 Basic Set Command is
disabled. 2 – Enabled Group 3 Basic Set Command, Group 2 Basic Set
Command is disabled. 3 – Enabled Group 2 and Group 3 Basic Set Command.
Parameter Number
5
Size (Byte)
2
Size (Byte)
2
Size (Byte)
1
Size (Byte)
1
Size (Byte)
1
Available Settings
0 ~ 32767
Available Settings
1 ~ 32767
Available Settings
0 ~ 11
Available Settings
0 , 1
Available Settings
0 ~ 3
Default value
30
Default value
240
Default value
11
Default value
0
Default value
3