Whirlpool RH4836 Series Istruzioni per l'installazione e manuale d'uso e manutenzione - Pagina 5
Sfoglia online o scarica il pdf Istruzioni per l'installazione e manuale d'uso e manutenzione per Cappa di ventilazione Whirlpool RH4836 Series. Whirlpool RH4836 Series 21. 30/36" (76.2/91.4 cm) convertible range hood installation instructions
Anche per Whirlpool RH4836 Series: Manuale d'uso e manutenzione (10 pagine)
4.
From the diagrams below,
select the diagram for your
installation.
Vented installations: Cut the vent
system and electrical wiring
access holes as required. Either
wiring hole can be used.
Non-vented installations: Cut only
the one 1-1/4" (3.2 cm) dia. wiring
access hole required. If wiring
through the top, use location
shown in VERTICAL vent systems.
If wiring through the back, use
location shown in HORIZONTAL
vent system.
5-1/4"
(13.3 cm)
centerline
1-1/4"
wall
5-1/2"
1-1/2"
(3.2 cm)
(14 cm)
(3.8 cm)
dia. hole
3-1/4" x 10" (8.3 x 25.4 cm)
RECTANGULAR VERTICAL
vent system
centerline
8" (20.3 cm)
dia. hole
1-1/4"
wall
5"
(3.2 cm)
(12.7 cm)
dia. hole
7" (17.8 cm)
ROUND VERTICAL
vent system
centerline
1-1/4" (3.2 cm)
cabinet
dia. hole
front
1/8"
(3.2 mm)
3-3/4"
5-1/4"
(9.5 cm)
(13.3 cm)
3-1/4" x 10" (8.3 x 25.4 cm)
HORIZONTAL
vent system
Prepare and install
the hood
WARNING
Excessive Weight Hazard
Use two or more people to move
and install range hood.
Failure to do so can result in
back or other injury.
7-1/2"
(19.1 cm)
5.
Remove terminal box cover.
Depending on your installation,
remove either back or top wiring
knockout.
2"
6.
(5.1 cm)
Remove the rectangular
damper/vent connector from
under the left side of hood. Set
connector and screws aside for
use if connecting to a rectangular
vent system.
For vented installations, go to
7-1/2"
(19.1 cm)
Step 7a.
For non-vented installations,
go to Step 7e.
2"
(5.1 cm)
7a.
For vented installations:
Insert the baffle plate into slot
behind grille. The locator bumps
should be at the top as shown.
Remove either top or rear
3/4"
rectangular vent knockout. If
(1.9 cm)
using round vent, remove both
7-1/2"
top rectangular and semi-circular
(19.1 cm)
knockouts.
terminal
box
cover
bumps
baffle
plate
7b.
Vertical rectangular vent:
Attach the damper/vent
connection with two screws as
shown.
Insert damper/vent connection
through wall
cutout and
into vent
7c.
Horizontal rectangular
vent: Attach damper/vent
connection to back of hood and
insert through the wall cutout and
into the horizontal vent.
Note: If the wall cap is directly
behind the vent connector, the
dampers in the wall connector
and cap MUST NOT interfere with
each other. Remove the vent
connector damper if they interfere.
7d.
Vertical round vent:
Fasten the round adapter to the
hood with two screws as shown.
Install round damper (purchased
separately).
7e.
For non-vented
installations: Check that the baffle
plate has not been installed in
slot behind grille. If it has,
remove the baffle plate
5