Connect Vent System
Connect the ventwork to the range hood. Seal joints with vent
clamps or duct tape to make secure and airtight. Check that the
backdraft dampers work properly.
Power Supply Cable Installation
1. For direct wire installations, run the home power supply
cable according to the National Electric Code or CSA
standards and local codes and ordinances. There must be
enough wiring from the fused disconnect (or circuit breaker)
box to make the connection in the hood electrical terminal
box.
For optional power supply cord kit (see the "Accessories"
section), follow the instructions in the "Make Electrical
Connections" section.
NOTES:
Use only with range hood cord connection kits that have
■
been investigated and found acceptable for use with this
model range hood.
Do not reconnect power until the installation is complete.
■
2. Remove the screw from the terminal box cover. Remove
terminal box cover and set aside.
A. Terminal box cover
B. Screw
Option 1 - Direct Wire Installations
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
A
B
A. White wires
B. Black wires
C. UL Listed wire connector
D. Green (or bare) ground wire
2. Use UL Listed wire connectors and connect white wires (A)
together.
3. Use UL Listed wire connectors and connect black wires (B)
together.
Electrically ground the blower.
Use copper wire.
Connect ground wire to green ground screw in
terminal box.
Failure to do so can result in death, fire, or
electrical shock.
4. Connect green (or bare) ground wire from power supply to
green ground screw in terminal box and securely tighten.
5. Install terminal box cover.
6. Reconnect power.
Make Electrical Connection
WARNING
Electrical Shock Hazard
G
D
C
A
B
E. Home power supply cable or
power cord accessory kit
F. UL Listed or CSA Approved
½" strain relief
G. Green ground screw
WARNING
Fire Hazard
E
F
13