Yamaha Clavinova CLP-970C Opuscolo di riferimento - Pagina 25

Sfoglia online o scarica il pdf Opuscolo di riferimento per Tastiera elettronica Yamaha Clavinova CLP-970C. Yamaha Clavinova CLP-970C 37. Yamaha digital piano owner's manual
Anche per Yamaha Clavinova CLP-970C: Manuale d'uso (giapponese) (24 pagine)

Yamaha Clavinova CLP-970C Opuscolo di riferimento
The following RPN messages can be received.
RPN
Data Entry *1
Parameter name and value range
MSB LSB
MSB LSB
00
00
mm -- *2
Pitch bend sensitivity
00
01
mm ll
Fine tuning
followed by 01 00 (=-87.4) cents.
00
02
mm --
Coarse tuning
127 127
--
--
RPN Null
state. Internal data is not affected.
*1 Refer to 1.2.4
*2 '--' indicates that the setting value is ignored.

1.2.23 Assignable controller

By assigning a control change number of 0...95 to a part, the specified effect can be con-
trolled.
This device allows two control change numbers (AC1 and AC2) to be specified for each
part.
The following parameters specify the effect of AC1 and AC2.
• Multi Part Parameter
1. AC1, AC2 PITCH CONTROL
2. AC1, AC2 FILTER CONTROL
3. AC1, AC2 AMPLITUDE CONTROL
4. AC1, AC2 LFO PMOD DEPTH
5. AC1, AC2 LFO FMOD DEPTH
6. AC1, AC2 LFO AMOD DEPTH
• Effect1 Parameter
7. AC1, AC2 VARIATION CONTROL DEPTH
(Valid if Variation Effect is assigned to a part as Insertion)
The AC1 control change number is specified by the Multi Part parameter AC1 CONTROL-
LER NUMBER, and the AC2 control change number is specified by the Multi Part param-
eter AC2 CONTROLLER NUMBER.
1.3 Channel mode messages
These messages specify the basic operation of a part.
1.3.1 All Sound Off
This message silences all currently-sounding notes on the corresponding channel.
However, the settings of channel messages such as Hold 1 and Sostenuto will be main-
tained.
Control# Parameter
Data Range
120
All Sound Off
0
1.3.2 Reset All Controllers
This message resets the following controllers to their default values.
Controller
Value
Pitch bend change
±0 (center)
Channel pressure
0 (off)
Polyphonic key pressure
0 (off)
Modulation
0 (off)
Expression
127 (maximum)
Hold
0 (off)
Portamento
0 (off)
Sostenuto
0 (off)
Soft pedal
0 (off)
Portamento control
Reset the portamento source note number that was received
RPN
Number unset, internal data is not affected.
NRPN
Number unset, internal data is not affected.
The following data is not changed
Parameter values specified by program change, bank select MSB/LSB, volume, pan, effect
send levels 1, 3, 4, RPN and NRPN.
Control# Parameter
Data Range
121
Reset All Controllers 0
1.3.3 All Note Off
This message turns off all notes which are currently on for the corresponding part.
However, if Hold 1 or Sostenuto are on, notes will continue to sound until these are turned
off.
Control# Parameter
Data Range
123
All Note Off
0
mm: 00-24 (0...+24 semitones)
Specify up to 2 octaves in semitone steps
mm ll:0000-100 cents
:
:
mm ll:64000 cents
:
:
mm ll:127127+100 cents
[Note]mm ll: 00 127 (=-87.5) cents is
mm: 40 - 64 - 88 (-24...0...+24 semitones)
This sets RPN and NRPN numbers to an unset
1.3.4 Omni Off
Perform the same processing as when All Note Off is received.
Control# Parameter
Data Range
124
Omni Off
0
1.3.5 Omni On
Perform the same processing as when All Note Off is received.
Control# Parameter
Data Range
125
Omni On
0
1.3.6 Mono
Perform the same processing as when All Sound Off is received, and if the value (mono
number) is in the range of 0...16, set the corresponding channel to Mode4* (m = 1).
Control# Parameter
Data Range
126
Mono
0...16
* Mode4 is a state in which only channel messages on the specified channel will be
received, and notes will be sounded individually (monophonically).
1.3.7 Poly
Perform the same processing as when All Sound Off is received, and set the corresponding
channel to Mode3*.
Control# Parameter
Data Range
127
Poly
0
* Mode3 is when channel messages will be received only on the specified channel,
and will be sounded polyphonically.

1.4 Program change

This message reports sound selection changes and changes the program number of the
receiving channel.
In order to include changes to the voice bank, Program Change and Bank Select messages
must be sent as a set (see 1.2.1).
When RevPROGRAM CHANGE=OFF for Multi Part Parameter, the program change for
that part is not received.

1.5 Pitch bend

This message conveys movements of the pitch bender.
This message is generally used to modify the pitch of a part, but the depth of the following
seven effects can be controlled.
The effect of this message can be modified by the following parameters.
• Multi Part Parameter
1. BEND PITCH CONTROL
2. BEND FILTER CONTROL
3. BEND AMPLITUDE CONTROL
4. BEND LFO PMOD DEPTH
5. BEND LFO FMOD DEPTH
6. BEND LFO AMOD DEPTH
• Effect1 Parameter
7. BEND VARIATION CONTROL DEPTH
(Valid when Variation Effect is assigned to a part as Insertion)
By default, the Pitch Control effect is applied.
If the Multi Part parameter Rcv PITCH BEND CHANGE = OFF, that part will not receive
pitch bend messages.

1.6 Channel aftertouch

This message conveys the pressure which is applied to the keyboard after playing a note in
order to create tonal changes (for an entire MIDI channel). The pressure can be controlled
for each part. This message will affect the currently-sounding notes.
The effect of this message will be determined by the settings of the following parameters.
• Multi Part Parameter
1. CAT PITCH CONTROL
2. CAT FILTER CONTROL
3. CAT AMPLITUDE CONTROL
4. CAT LFO PMOD DEPTH
5. CAT LFO FMOD DEPTH
6. CAT LFO AMOD DEPTH
• Effect1 Parameter
7. CAT VARIATION CONTROL DEPTH
(Valid when the Variation Effect is assigned to a part as Insertion)
By default, there will be no effect.
If the Multi Part parameter Rcv CHANNEL AFTER TOUCH = OFF, that part will not
receive Channel Aftertouch.
MIDI Data Format
25
CLP-970