Altronics Proart A 5030 Istruzioni per l'uso

Sfoglia online o scarica il pdf Istruzioni per l'uso per Amplificatore Altronics Proart A 5030. Altronics Proart A 5030 4. Altronics proart multi-room audio distribution system

Operating Instructions

A 5030
A 5030 Matrix Control Unit
A 5036 Remote Control Wallplate
Overview
Congratulations on purchasing a Proart A 5030 multi-source,
multi-room audio distribution system. This system allows up
to 8 audio program sources (eg tuner, CD, DVD) to be distrib-
uted to six different rooms or zones. It enables the selection
of a desired source and volume setting in each room inde-
pendently of other room settings via infra red
re-transmission. A complete system consists of control wall
plates, input matrix controller, zone amplifier and infra red
(IR) transmitters.
Features
• Remote source and volume selection via wall plate or IR
remote control
• Source selection and volume level display
• Up to 6 speaker zones
• Up to 8 input sources
• Wallplates can be situated up to 50m from controller
• Cat 5 cable and RJ45 connections for easy installation
• Local 3.5mm source input for MP3 players etc.
• Wall plates fit standard electrical wall box
• Easy to install and configure
• Multiple wall plates per zone
• 3 external contact switch outputs
• Priority input
• IR repeaters for external source control (CD, tuner, DVD)
Distributed by Altronic Distributors Pty. Ltd. Perth. Western Australia.
Phone: 1300 780 999 Fax: 1300 790 999
Internet: www.altronics.com.au
www.altronics.com.au
Installation
1. Connect the wallplates using figures 2 & 3 as a guide.
Figure 3 must be used if more than 1 wallplate is used per
zone.
The wall plates will fit into a standard single gang electrical
wall box. Connect the RJ45 plug and cable to either of the
sockets on the rear of the wall plate, with the connecting
cable wired pin 1 – pin 1, pin 2 – pin 2 etc, for all 8 pins.
2. Each wallplate used in the sys-
tem must be assigned a zone num-
ber. To assign a zone number turn
the rotary switch on the rear of the
wall plate (figure 1) to one of the
settings listed below:
Zone 1 – rotary switch set to no. 1
Zone 2 – rotary switch set to no. 2
Zone 3 – rotary switch set to no. 3
Zone 4 – rotary switch set to no. 4
Zone 5 – rotary switch set to no. 5
Zone 7 – rotary switch set to no. 7
Zone 8 – rotary switch set to no. 8
Switch settings 9 and A to F are not used.
If you wish to have multiple wallplates controlling the same
zone, ensure all rotary switches for that zone are set to the
same position.
A 5036
Figure 1: Wall plate
rear detail.
Rotary
Switch
RJ45 RJ45