AluTeam BR 13x-3 Manuale di istruzioni per il montaggio - Pagina 13

Sfoglia online o scarica il pdf Manuale di istruzioni per il montaggio per Camion AluTeam BR 13x-3. AluTeam BR 13x-3 14. Box kits

4. Maintenance

5. Service, Spare parts

6. Waste disposal of used boxes or component parts

Assembly instructions BR 133-3 to 139-3
For the maintenance of the structure, check all screws are tight (also in
case of sliding doors!) at regular intervals but at least once a year. Also
check the prescribed torque in the process.
Locks and closing cylinders are maintenance parts. They must be
kept serviceable with lubricants when necessary. Locks seized due
to poor maintenance are not a reason for complaint.
Clean the structure with a steam jet blower, at the earliest after
Clean the structure with a steam jet blower, at the earliest after
6 weeks. In order to avoid damage to the paint, keep
6 weeks. In order to avoid damage to the paint, keep
nozzle at a minimum distance of approx. 300 mm. The
nozzle at a minimum distance of approx. 300 mm. The
maximum water temperature is 60°C, the maximum oper-
ating pressure is 100 bar, and the pH value of the clean-
ing agents is 4 - 10.
After that, flush immediately with sufficient amounts of clear wa-
ter. Remove rust film on stainless-steel parts (including the frame)
with normal household stainless steel cleaners.
Treat all seals with a rubber care agent after every cleaning.
In case of questions related to the assembly, our
be glad to help you:
Tel: +49 (0)521-41 73 11-30, Email: [email protected]
If you require
spare
parts, please contact your responsible sales repre-
sentative or call us at: +49 (0)521 - 41 73 11 - 10
Please send e-mails to: [email protected]
You can remove the metallic layers from the foam core and have
them recycled together with aluminium via the scrap trade. The
same applies to the steel and/or stainless steel components of the
frames.
A PUR foam core can be burned in thermal waste treatment systems
without contaminating the environment. The energy contained in
the insulation material is converted into primary energy in this case.
Plywood, too, can be used to generate energy. Odour nuisance due
to the ammonium additives in the binding agents are to be avoided.
Generally, they can be burned as chipboard in wood furnaces with
50 kW minimum nominal thermal capacity. They are subject to
significantly stricter carbon monoxide limit values than solid wood.
Mostly, only automatically fed systems comply with these values.
It is essential that you also consider the proper disposal of the
foam in the floor area.
Tip:
Information on this can be found in a leaflet published by the
„Fachvereinigung Polystyrol - Extruderschaumstoff (FPX)",
Odenwaldring 68, 64380 Rossdorf (www.fpx-daemmstoffe.de).
Status 03/2022
Former instructions lose their validity.
Customer Service
will
13 / 14