Akron 9301 Istruzioni per l'uso - Pagina 2
Sfoglia online o scarica il pdf Istruzioni per l'uso per Strumenti di misura Akron 9301. Akron 9301 3. Portable flow meter
Anche per Akron 9301: Istruzioni per l'uso (5 pagine)
When the unit is powered on, three red LED mode lights on the left side of display will appear. Each of these
lights aligns with particular function marked on the bezel face.
The unit has three operating functions:
1. Flow GPM or LPM - Actual Gallons or Liters per minute flowing. Flows up to 300 GPM or 1200 LPM will
display in single increments. Flows over 300 GPM or 1200 LPM will display every 10 units.
2. Flow TOTAL - Total gallons or liters flowed since unit was powered up. Figures displayed must be
multiplied X 100 to get a total.
3. Pressure PSI or kPa – Shows actual pressure.
At the time of power up, all three mode lights will appear with four zeros. In sequence a number value will appear,
followed by GAL/LPM, PSI/kPa, Pipe Size (2.5) and finally 0. This will be complete in a few seconds
The unit is now ready for operation.
tO reaD:
GpM/LpM: - Press and release left (flow) button to place mode light on GPM/LPM. The actual GPM or LPM
will appear on display.
tOtaL FLOW: - Press and release left (flow) button to place mode light on TOTAL. The figures displayed
must be multiplied by 100 to give gallons or liters flowed.
psi/kpa: - Press and release the right (pressure) button to place the mode light on PSI/kPa. Actual pressure
will appear on the display.
trOuBLesHOOtinG
prOBLeM
Display does not illuminate
GPM/LPM shows 0 & water is flowing
LED Dim
Lens Foggy
dEAD displayed
EPrL displayed
EPrH displayed
HOW tO recaLiBrate:
1. Press and hold BOTH buttons simultaneously for approximately 15 seconds the unit display flashes caL (calibration).
Release. After a few seconds siZe will appear and all 3 mode lights will illuminate.
2. Press and release the LEFT button. pres (pressure) will appear.
3. Press and release the RIGHT button. The word ZerO (displayed 2Ero) will appear and the PSI/kPa/bar
mode light will flash.
4. Press and release the Right button. ZerO will start flashing. After a moment 0 will appear.
5. Power off the unit and back on again. The unit is now zeroed out and ready for operation.
The procedure need not be repeated unless the Pressure Transducer (9) or the meter is replaced.
sOLutiOns
A problem exists with the power. Check connections.
Check battery. Recharge if needed.
Check cable (16) - Replace if needed.
Stop water flow and remove Flow Sensor (7) and spin the paddlewheel to be
sure it spins freely. If still no reading - replace the sensor.
Hold the left button down for 5 seconds to brighten.
Fog should dissipate soon after use with LED's lighted.
A problem exists with the power. Check connections. Check if battery needs
recharging.
Check cable (16) - replace if necessary and recalibrate.
Check for vacuum in line
Check power & ground connections and recalibrate.