Ambient Technologies RCSTEBA Manuale di installazione e istruzioni per l'uso - Pagina 7
Sfoglia online o scarica il pdf Manuale di installazione e istruzioni per l'uso per Telecomando Ambient Technologies RCSTEBA. Ambient Technologies RCSTEBA 11. Thermostatic on/off and blower remote control– 120vac
Manual Mode:
1. Press the ON button once to turn on the appliance. Press the OFF button to
turn it off.
Thermostatic mode:
1.
Press the AUTO button to enter the thermostatic mode.
2.
In thermostatic mode, press the ON /
desired set temperature.
3.
Once the setting is completed, the transmitter will automatically turn on the
fireplace when the room temperature is below the set temperature and turn off
the appliance when the room temperature is above the set temperature within 1
degree.
4.
There will be a slight delay in the response of the unit (on/off) to a temperature.
Room temperature is monitored every 3 minutes.
5.
Press the Auto button to exit the thermostatic mode (Return to Manual Mode).
The transmitter will be in the manual on/off mode and receiver / transmitter will
maintain the previous settings of Fan speed & blower Delay on & Delay off time.
3-Speed Blower Control:
Note: Blower operates with flame on only
1.
Press FAN button once to enter blower speed setup mode at low speed
initially and one of the three blade icon will display darken on LCD.
2.
Continue to press FAN button to set up the blower speed you desire.
3.
If there is no input within 3 seconds, the new setting will be transmitted to
receiver. If fireplace is on, the blower speed will take effect right away; if
fireplace is off, the receiver will remember this setting and blower is still off.
4.
If you continue to press FAN button while fire is on or off the FAN icon will
disappear and turn the blower off.
Blower On Delay Time and Off Delay Time Setting:
Note: Blower operates with flame on only
1.
Hold FAN button for 5 second and two numbers will show up in LCD screen.
The upper one is On Delay Time and the bottom is Off Delay Time.
Δ
2.
Use the ON /
∇
3.
Use the OFF /
4.
If there is no input within 3 seconds, the new setting will be transmitted to
receiver.
5.
The default settings for both transmitter and receiver are 5 minutes for On
Delay Time and 8 minutes for Off Delay Time, as shown in this picture.
NOTE
The most efficient setting for your fireplace blower is when blower comes
on and off, it is blowing warm air only not hot air. Giving the fireplace as
much time to discharge as much warm air as possible before turning off.
50D0112
RCSTEBA Installation & Operating Manual
Rel 1.0 April 2009
Δ
button or OFF /
button to set the desired On Delay Time from 0 to 15 min.
button to set the desired Off Delay Time from 0 to 15 min.
∇
button to set the
Page 7 of 10