- ページ 30

サーバー Asus AP3000のPDF ハードウェア・リファレンス・マニュアルをオンラインで閲覧またはダウンロードできます。Asus AP3000 42 ページ。 Dual pentium ii server platform

Asus AP3000 ハードウェア・リファレンス・マニュアル
• 4-10. Front Cooling Fans
The front cooling fan module consists of a control board, a hard disk
drive LED status board, and two cooling fans. The message LED
board mounted in the front of the cooling fan module consists of five
sets of LEDs to represent the status of up to five hard disk drives.
Each set has three LEDs which can show the power, activity, and
status of each hard disk drive.
The front cooling fans' main purpose is to cool the hard disk drives.
These fans can be removed by using a small screw driver to push the
eject mechanism in the fan module. The eject mechanism is behind a
small hole as circled below. There are two individual 2 1/4 inch (6cm)
fans secured by four screws on each fan. The ASMA software will
report an error message when any of these two fans malfunctions.
Lower Fan
IMPORTANT
Usually, the rotation of the fan sends air toward the manufacturer's
label on the center of the fan.
30
IV. Hardware Setup
Front Cooling Fan Control Board
(mounted with the component side
facedown)
ß‚§‚
Hard Disk Drive Message Board (LEDs)
AP 3000 Hardware Reference Guide
Upper Fan