- ページ 36
サーバー Asus AP3000のPDF ハードウェア・リファレンス・マニュアルをオンラインで閲覧またはダウンロードできます。Asus AP3000 42 ページ。 Dual pentium ii server platform
Power Supply Information
Output Voltage Regulation, Ripple, and Noise
Output Voltage Limits (Vdc)
Output
Min
1
3.17V
2
4.80V
3
11.40V
4
-4.50V
5
-10.92V
6
4.75V
Output Current Capacity
Output Nom (Vdc) Max (A) Min (A)
1
3.3V
2
5.0V
3
12.0V
4
-5.0V
5
-12.0V
* Total output power for 3.3V and 5V combined shall be 210W
Input Voltage
Range
Min (V) Nom (V)
Range 1
90
Range 2
180
Safety
The power system meets all applicable clauses for UL 1950 2nd edition with-
out D3 deviations. The power system passes all tests for CUL and TUV
safety.
EMI
The power system, operating with resistive load, meets FCC class B and
CISPR 22 class B conducted limits.
36
IV. Hardware Setup
Nom
Max
3.30V
3.46V
5.00V
5.25V
12.00V
12.60V
-5.00V
-5.50V
-12.00V
-13.20V
5.00V
5.25V
*20.0
1.0
*45.0
2.0
12.0
0.5
0.5
0.0
0.5
0.0
Max (V)
120
137
230
265
AP 3000 Hardware Reference Guide
Ripple/Noise
Maximum
50mV
p-p
50mV
p-p
120mV
p-p
120mV
p-p
120mV
p-p
50mV
p-p