Installation

2
READ COMPLETE INSTALLATION
INSTRUCTIONS AND TEMPLATE
BEFORE STARTING
Attention Installer:
• Installation work and electrical wiring must be done
b y q u a l i f i e d p e r s o n ( s ) i n a c c o r d a n c e w i t h a l l
a p p l i c a b l e c o d e s a n d s t a n d a r d s , i n c l u d i n g f i r e -
related construction.
• 120V may cause serious injury from electrical shock.
D i s c o n n e c t e l e c t r i c a l p o w e r t o f u r n a c e b e f o r e
starting installation.
• Wear safety glasses, work gloves.
• When drilling or cutting into ducting be extremely
careful not to damage air conditioner coils or other
furnace parts.
• This unit must be installed on ducts at least 10" wide.
• Do not install this unit where extreme temperature
exist (below 45°F-above 145°F).
INSTALLATION TIP. Before starting , fully plan
out the installation. Check for the locations of
h u m i d i f i e r, b y p a s s c o l l a r a n d d a m p e r, t h e
length and type of ducting required, the water
supply, the water drain, the electrical wiring .
This will ensure your installation goes as easily
and quickly as possible.
1. The humidifier body mounted level on the return air
d u c t
( t o
h e l p
e v e n
evaporation pad).
2. The humidifier body and bypass duct are installed at
e y e l e v e l , e a s i l y a c c e s s i b l e f o r i n s t a l l a t i o n a n d
routine maintenance.
3. Distance between centers of humidifier body (on
return cold air duct) and bypass inlet (on the warm
air supply duct ) are no more than 30" (to allow for
best air flow).
4. The bypass damper is fully opened.
5. The bypass inlet opening should be at least 6" above
any restrictions (e.g . the air conditioning coils)
inside the duct.
6. The humidifier and bypass collar are at the same level.
7. Take the most direct route to join humidifier and
bypass collar.
w a t e r
d i s t r i b u t i o n
a c r o s s
INSTALLATION
STEP #1: RIGHT HAND DUCTING
OR LEFT HAND DUCTING
Depending on your furnace or for convenience of your
i n s t a l l a t i o n i t m a y b e n e c e s s a r y t o c o n v e r t t h e
humidifier for left hand ducting or right handing
ducting . Follow the steps below to switch the side
which bypass duct will attached to the unit.
1. Remove the humidifier front cover secured in place
with 10-24 plastic thumb screw at the bottom of the
cover .Tilt the about 1/2" away from the body and lift
the cover up to free the hooks at the top of the body.
2. Remove all lose components packaged inside. With
a firm pull, disconnect the water tube from the water
nozzle and remove the evaporator pad assembly by
sliding it toward the top of the humidifier, and then
lifting it out.
3 . R e m o v e t h e t w o # 6 s c r e w s w h i c h h o l d t h e
humidifier side in place , lift the humidifier side out
of the right hand position, turn the part and place it
on other side of the body.
4. Use two #6 crews removed to secure the humidifier
side in the left hand side.
IDEAL INSTALLATION
Figure 1
SUPPLY DUCT
WARM AIR
Damper fully open
STEP #2 MOUNTING THE HUMIDIFIER ON THE DUCT
1. Use adhesive tape to affix the template onto the duct
in the selected location. Use the level line to template
and level to ensure the humidifier will be level.
2. Drill the 3 marked 1/8" cabinet mounting holes.
3. Drill 2 marked 7/32" cabinet position holes.
4. Cut out the area marked on the template for the
humidifier plenum.
RETURN DUCT
COLD AIR
10" wide duct minimum
No more
than 30"
Bypass collar and
unit level
Bypass tube pulled
tight and cut to length
Water flowing to drain