Software Description
The main window (Figure 3) contains the system menus, system level controls, device information and
logging status. The main window contains only one tab "Prox" to configure the parameters to run
proximity. The prox data and its average data is also plotted in this tab. The application polls the prox
raw data continuously.
Figure 3:
GUI Main Window
4.1
Connect Software to Hardware
On startup, the software automatically connects to the hardware. On successful initialization, the
software displays a main window, containing controls pertinent to the connected device. If the software
detects an error, an error window appears. If "Device not found or is unsupported" appears, verify the
correct daughterboard is properly connected to the EVM controller board. If "Cannot connect to EVM
board" appears, verify the USB cable is connected. When the EVM controller board is connected to
the USB, a green LED lights on power up to indicate the USB cable is connected and providing power
to the system. The LED will remain lit until the any software application opens the controller. The light
will then be switched off so that it will not interfere with any light measurements.
If the EVM board disconnects from the USB bus while the program is running, it displays an error
message and then terminates. Reconnect the EVM board and restart the program.