コントロールユニット Atkinson Electronics A0217のPDF マニュアルをオンラインで閲覧またはダウンロードできます。Atkinson Electronics A0217 16 ページ。 Generator start control module
Electric Start High Speed Gas/ Propane Generator without Starter Control Box
This application matches high speed generators that do not include starter control boxes. Propane generators may be the type
that ground the ignition to shut down or have an automotive type coil ignition. The wiring configurations are shown for both
automotive and magneto type with or without fuel valves. High speed (3600 RPM) generators may need the crank disconnect
hertz adjustment set to 20Hz or less to avoid over driving the starter.
Low Speed Gas/ Propane Generator with Safeties
The low speed gas/ propane generators also wire the same as in application 2. However, the installer should determine
ignition type and oil and high temperature safety shutdown wiring. The GSCM is looking for oil and high temperature safety
switches that short to ground on a low oil pressure or high temperature condition.
www.atkinsonelectronics.com
800.261.3602
12
Circuit Board Division
Revised 09/18