TROUBLESHOOTING
Always disconnect power to the fixture before performing any service or maintenance.
and ultraviolet resistant face shield, if troubleshooting SANITAIRE
IMPORTANT: This unit is to be serviced ONLY by qualified, and appropriately trained and/or licensed personnel.
Problem
SANITAIRE
®
unit
not operating.
Internal blower(s) not
functioning.
( 1 ) STER-L-RAY
®
Germicidal
Lamp not operating
All STER-L-RAY
®
Germicidal
Lamps not operating.
If the above measures fail to correct the problem(s), contact our UV Application Specialists. Contact options can be found in
the "User Assistance" section.
TECHNICAL SPECIFICATIONS
Model Numbers
Blower Capacity: (Cubic Feet per Minute)
Nominal Fixture Capacity j: (Cubic Feet per Minute)
Max Treatment Capacity: (Cubic Feet per Hour)
Max Room Size @ 3 Air Changes/Hour: (Cubic Feet)
Max Room Size @ 4 Air Changes/Hour: (Cubic Feet)
Max Room Size @ 5 Air Changes/Hour: (Cubic Feet)
Max Room Size @ 6 Air Changes/Hour: (Cubic Feet)
Dimensions
Electrical:
Lamp Data:
Weight:
j Fixture capacity incorporates an estimated allowance for airflow friction loss across filter and fixture.
k Ultraviolet output at 254nm at 100 hours and 80°F (approximate).
All specifications, dimensional data, etc. are approximate and subject to change without notice.
14
Use personal protection equipment, such long sleeves with no gaps between cuffs and gloves,
Table 1 – Troubleshooting
Possible Cause
No electrical power.
Power connection to fixture is
loose or disconnected.
Loose power connection.
Faulty blower motor.
STER-L-RAY
®
Germicidal Lamp
not properly seated.
STER-L-RAY
®
Germicidal Lamp
not operating.
Surelite
™
Ballast not functioning.
STER-L-RAY
®
Lamps not installed.
Interlock switch open.
Interlock switch faulty.
Table 2 – Technical Specifications
Length: (Inches)
Width: (Inches)
Height: (Inches)
Volts: (Volts)
Amps: (Amps)
Line Frequency: (Hertz)
Lamp Model:
Ultraviolet Output k: (Watts/Lamp)
Pounds: (lbs.)
.
®
Corrective Action
Verify that the unit is connected to a live
power source.
Verify power connection to fixture is
fully engaged.
Confirm connection to blower; connection is tight and
makes full contact.
Replace blower motor.
Confirm contact of lamp and lampholder is tight, and
that lampholder is making full contact with lamp.
Swap suspect lamp with known good lamp position. If
suspect lamp still does not operate, replace lamp.
If steps above do not fix problem, replace ballast
corresponding to non-functioning lamp.
Install lamps.
Confirm access cover is on and latched.
Replace interlock switch.
RSM2680
2,680 CFM
2,000 CFM
120,000 ft³
40,000 ft³
30,000 ft³
24,000 ft³
20,000 ft³
78-7/8"
60 Hz
05-0864
35 W
365 lbs.
33"
31"
120v
12 A