- ページ 8

扇風機 Atlas DonaireのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Atlas Donaire 13 ページ。 52” ceiling fan

2. Motor to Receiver Electrical Connections:
Connect the WHITE wire from the fan to the
WHITE wire marked "TO MOTOR N" from the
Receiver. Connect the BLACK wire from the fan
to the BLACK wire marked "TO MOTOR L" from
the Receiver. Proceed to secure all wire
connections with the plastic wire nuts provided.
Connect the BLUE wire from the fan to the
BLUE wire marked "For Light" from the receiver.
Proceed to secure all wire connections with the
plastic wire nuts provided. (Fig. 11)
Note: Fan must be installed at a maximum
distance of 40 feet from the transmitting unit for
proper signal transmission between the
transmitting unit and the fan's receiving unit.
3. Receiver to House Supply Wires Electrical
Connections: Connect the WHITE wire (Neutral)
from the outlet box to the WHITE wire marked
"AC in N" from the receiver. Connect the BLACK
wire (Hot) from the outlet box to the BLACK wire
marked "AC in L" from the receiver. Secure all
wire connections with the plastic wire nuts
provided. (Fig. 11)
4. If your outlet box has a GROUND wire
(Green or Bare Copper) connect this wire to
the Hanger Ball and Hanger Bracket Ground
wires. If your outlet box does not have a
Ground Wire, then connect the Hanger Ball
and Hanger Bracket Ground Wires together.
Secure wire connection with the plastic wire
nut provided. (Fig. 11)
OUTLET BOX
BLACK (HOT)
BLACK ("AC IN L")
RECEIVER
BLACK ("TO MOTOR L")
6
WHITE (NEUTRAL)
GREEN OR BARE
COPPER (GROUND)
WHITE ("AC IN N")
WHITE ("TO MOTOR N")
(3 GROUND WIRES
GROUND-
ON CEILING FAN)
(GREEN)
WHITE (NEUTRAL)
Figure 11