Escort5580TC and EMS-100 – Thermostat Output Control
Application:
This application will provide an example for setting the temperature depending on the
armed status of the panel. The Escort will change the temperature to the programmed
setting when the panel is armed in the Stay or Away setting, or when disarmed.
Equipment:
-
Power 832 v2.x or greater
-
LCD5500 v2.1 or greater (optional)
-
Escort5580TC Module
-
EMS-100 Thermostat
-
EMS-ITS Internal Temperature Sensor (optional)
-
EMS-OTS Outdoor Temperature Sensor (optional)
Special Notes:
1. The Application Note assumes that the EMS-100 will be used to control both heating and cooling.
2. The user cannot 'temporarily' change the temperature. Any time the user manually changes the
temperature set point for an Occupancy Setting, it will change to the new setting.
Program Sections:
Procedure:
For information regarding how the Escort is programmed, please refer to the Escort5580TC Installation
Manual.
Step 1 – Thermostat 1 Options – Escort Section [800]
Turn Option [01] ON to enable the thermostat.
Turn Option [02] ON if an EMS-OTS outdoor temperature sensor is connected.
Turn Option [03] ON if the thermostat will be used to control heating.
Turn Option [04] ON if the thermostat will be used to control cooling.
Turn Option [05] ON so the Day Occupancy Setting will always activate by output control.
Turn Option [06] ON so the Night Occupancy Setting will always activate by output control.
Turn Option [07] OFF as the Aux Occupancy Setting will not be used.
Turn Option [08] ON so the Away Occupancy Setting will always activate by output control.
Step 2 – Thermostat 1 Day Occupancy Setting Output Option – Escort Section [803]
Program data [01] for output control only. The user will always have manual control as well.
Escort Section [800]
Escort Section [803]
Escort Section [804]
Escort Section [808]
Escort Section [809]
Escort Section [818]
Escort Section [819]
Panel Section [010], [143]
- Thermostat 1 Options
- Thermostat 1 Day Setting Output Option
- Thermostat 1 Day Setting PGM Output
- Thermostat 1 Night Setting Output Option
- Thermostat 1 Night Setting PGM Output
- Thermostat 1 Away Setting Output Option
- Thermostat 1 Away Setting PGM Output
- PC5208 PGM Output Programming