- ページ 3

ゲートウェイ 3onedata GW1114-4DIのPDF クイック・インストール・マニュアルをオンラインで閲覧またはダウンロードできます。3onedata GW1114-4DI 3 ページ。 Modbus gateway

3onedata GW1114-4DI クイック・インストール・マニュアル
The model II of this series provides 5-Pin
5.08mm pitch terminal blocks. The serial
port is isolated and its pin definitions are
as follows:
PIN
1
2
3
RS-485
D+
D-
GND
RS-422
T+
T-
GND
【Checking LED Indicator】
The device provides LED indicators to monitor the device
working status with a comprehensive simplified
troubleshooting; the function of each LED is described in the
table as below:
LED
Indicate
Description
PWR is connected and running
ON
normally
PWR
PWR is disconnected and running
OFF
abnormally
System runs normally
Blinking
The system is not running or running
RUN
OFF
abnormally
System is running abnormally
ON
Copper port has established an
ON
active network connection.
LINK
Copper port is in a network activity
Blinking
(1-2)
state.
Copper port has not established an
OFF
active network connection.
No data or abnormal data is being
OFF
TX(1-4)
transmitted through serial port.
Blinking
Serial port is transmitting data.
Serial port is not receiving data or
OFF
RX(1-4)
receiving data abnormally
Blinking
Serial port is receiving data.
【Logging in to WEB Interface】
This device supports WEB management and configuration.
Computer can access the device via Ethernet interface. The
way of logging in to device's configuration interface via IE
browser is shown as below:
4
5.
Step 1
Configure the IP addresses of computer and the
device to the same network segment(The network
R+
R-
segment of Network Port 1 is 1, and the network
segment of network port 2 is 8), and the network
between them can be mutually accessed.
Step 2
Enter device's IP address in the address bar of the
computer browser.
Network Port 1:
Network Port 2:
Step 3
Enter device's username and password in the login
window as shown below.
Step 4
Click "OK" button to login to the WEB interface of
the device.
Notes:
The default IP address of the device network port 1 is
"192.168.1.254", port 2 is "192.168.8.254".
The default username and password of the device are
"admin".
If the username or password is lost, user can restore it to
factory settings via device DIP switch or management
software; all modified configurations will be cleared
after restoring to factory settings, so please backup
configuration file in advance.
Please refer to user manual for specific configuration
method of logging in to WEB interface and other
configurations about network management function.
【Specification】
Panel
100M Copper Port
10/100Base-T(X) self-adapting RJ45
port
Serial Port
3IN1 RJ45 interface or RS-485/422
terminal block with isolation
Indicator
Power indicator, Running indicator,
Copper port connection indicator,
Serial
port
receiving data indicator
Power supply
Input power supply
12~48VDC
Access
terminal
3-pin 5.08mm pitch terminal blocks
block
Power
consumption
Model I
No-load: 2.16W@12VDC
Full-load: 3.00W@12VDC
Model II
No-load: 2.94W@12VDC
Full-load: 2.94W@12VDC
Working
environment
Working
-40~75℃
temperature
Working humidity
5%~95% (no condensation)
Protection grade
IP30(metal)
transmission
and