- ページ 13
セキュリティシステム Abus AZSG10005のPDF インストール手順とユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Abus AZSG10005 19 ページ。 Wired outdoor siren
Installation
Step 4: Pre-configuration via jumper
If you would like to change
o the siren duration from the default value [3 min.], and/or
o the circuit monitoring from the default values, and/or
o you would like to set the volume differently to the default value, then:
Slide the inner housing to the left, to release it from the catch.
Now open the inner housing by undoing the screws at the top and bottom and set the values
using the jumpers [LK2] to [LK9] as required.
Close the inner housing again using both screws.
Snap the housing back into the mount by sliding it to the right.
If you wish to set the mode for the power supply, open the terminal block and set the jumper
[LK1] accordingly.
Polarity:
+ve
Activated by positive signal, 12 V fitting.
-ve
Activated by negative signal, 0 V fitting.
Description of jumpers:
Select from SAB or SCB mode
[LK1]
Tamper notification with +ve or -ve polarity
[LK2]
Siren activation with +ve or -ve polarity
[LK3]
Flashing light activation with +ve or -ve polarity
[LK4]
[LK5]
Monitoring the signal for activating the siren and flashing light.
Please note the following instructions for this function.
Cyclical siren duration
[LK6]
Siren duration of 15 minutes
[LK7]
Siren duration of three minutes
[LK8]
[LK9]
Select siren volume from
STD = 100 dB(A) @ 1 m or
SPN = 85 dB(A) @ 3 m
13