- ページ 9
体重計 ADE ZW60-45のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。ADE ZW60-45 20 ページ。 Electronic table scales
6.6
Presetting the maximum and minimum values for audible alarm
The ZW60 checkweighing scale has a programming function that emits an audible signal when
a user-defined number of pieces or weight is either reached (minimum) or exceeded
(maximum).
More information about the audible signal setting can be found in chapter "Parameters".
- In weighing mode, press the HI LIMIT or LOW LIMIT button to recall the currently stored
maximum or mini-mum weight.
- In counting mode, press the HI LIMIT or LOW LIMIT button to recall the currently stored
maximum or mini-mum quantity.
- To change the values, keep the button pressed in the respective mode until the current
value flashes on the display.
- To reset the value to zero, press the C button.
- Now enter the maximum or minimum value using the numeric keypad and confirm the
selection with HI LIMIT or LOW LIMIT.
- The scale will return to weighing mode.
- When the weighing surface is loaded, arrows on the display indicate whether the weight is
below or above the values and an audible signal is emitted based on the settings made (see
chapter PARAMETERS).
Both values are set:
The minimum value is set
and the maximum value is
zero:
The minimum value is
zero and the maximum
value is set:
Both values are set, but
the minimum value
exceeds the maximum
value:
Please note that to be able to use this control function, the weight must
be 20 times the dividing incre-ment of the scale.
- To disable the control function, enter zero for the minimum and maximum values as
described above and save your entry with ZERO.
6.7
Totaliser
The ZW60 series scale can be set so that successively applied weights are added to the
scale's totaliser either automatically or by pressing the M+ button. The selection of manual or
automatic totalisers can be changed using the parameter settings.
The totaliser is enabled only in weighing mode. This function is disabled in counting or
percent weighing mode.
When the totaliser is enabled, M+ appears flashing on the display.
ZW60-210531-Rev006-UM-en
When the weight is within the set values, the display
shows OK.
The display shows OK as long as the weight is lower than
the set minimum value. When the applied weight exceeds
the minimum value, the display shows HIGH.
The display shows LOW as long as the applied weight is
lower than the set maximum value.
When the applied weight exceeds the maximum value, the
display shows OK.
The audible signal is not emitted.
The display shows LOW as long as the applied weight is
lower than the set minimum value and HIGH if the weight
is greater than the set minimum value.
9