浄水器 Austin Springs AS-RO-75のPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。Austin Springs AS-RO-75 9 ページ。 Reverse osmosis water filter system
Installation Steps
Step 1: Connect the Water Feed Adapter
The Water Feed Adapter can convert to larger and smaller pipe threads. (Tip #4)
1 Turn off the cold-water supply by locating the valve
under the sink Confirm it is off by turning the sink faucet
onto cold No water should be running through
2 Disconnect the faucet connector pipe from the cold-
water supply Place a towel underneath to catch any
drips
3 Attach the Water Feed Adapter to the cold water supply
Re-connect the faucet connector pipe to the Water Feed
Adapter
1 –
"
4 Connect the
RED tubing to Water Feed Adapter
4
Step 2: Install Drinking Water Faucet
Faucet
Drain Input
Drain Output
Faucet Cuff
O-Ring
Counter
Split Washer
Spacer
Lock Washer
Lock Nut
Tube Insert
Collar
Brass Nut
Tubing
6
4
(See Tip #1)
7 –
"
1 Using the existing
hole or after having one drilled,
8
clean and dry the area
2 Slide the faucet cuff and o-ring over the faucet base
threads
3 Insert the faucet, threaded side down, into the hole
4 From under the sink, slide the split washer, spacer,
and lock washer on and firmly secure it with the lock
nut
1 –
5 Insert the black
"
tubing onto the drain input nipple
4
3 –
6 Insert the black
"
tubing onto the drain output
8
nipple
7 Assemble the compression fitting
(See Tip #2)
8 Insert the compression fitting into the threaded
end of faucet, tighten nut Once it is tightly in place,
gently pull tubing to confirm it is secure
Step 3: Install Drain Saddle
3 3
1 Choose a convenient spot for installing the drain saddle and tubing Installing on a horizontal
portion of the drain pipe will minimize dripping noise
1 –
"
2 Drill a
hole Paste the black sticky pad over it ensuring the holes align
4
3 Cut the end of the
3
the drain saddle by tightening the two screws and hex nuts Ensure that the hole in the drain
saddle is aligned with the hole that was drilled in the drain pipe
3 –
"
4 Connect the
8
1
Step 4: Install the Vertical Filters — Stages 3, 2 and 1
O-Ring
Step 5:
Install Tank Shut-off Valve
1 Use Teflon tape to wrap metal thread at
the top of the tank Wrap clockwise 10-
15 turns
2 Screw on Tank Shut-Off Valve and
tighten up by hand Do not over tighten
3 Connect the YELLOW tubing to the
Quick-Fitting of Tank Shut-Off Valve
3 –
"
Black tubing from the faucet drain output to the desired length Mount
8
BLACK tubing to the drain saddle
(See tip #1)
1 Inspect filter housing O-ring should be in the groove at the top
*Optional: Use Food-grade silicon jelly on O-ring for a better seal
2 Unwrap the filter cartridges; follow the color-coded stickers on the
packaging
3 Place each filter cartridge into its housing Make sure the center hole of
each filter is aligned onto the raised ring at the bottom of each housing
4 Screw each filter housing (with loaded cartridges) into the RO manifold
Ensure each cartridge is aligned to each of the center posts of the
RO manifold Twist clockwise by hand Use housing wrench to tighten
1 –
about
turn Overtightening may cause damage and leaks
4
5 Repeat these steps for each cartridge
in a certain direction — the end with the rubber washer faces up
NOTE:
the second stage must go
3
2
1
1
7