- ページ 7
薪ストーブ Austro Flamm KOKO 2.0のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Austro Flamm KOKO 2.0 20 ページ。
Koko 2.0
1. TECHNICAL DATA
As a stove of construction type 1, it is possible to
connect it to the flue pipe of an existing other stove or
another hearth for solid fuels, as long as the chimney
complies with DIN 4705, Part 3
TECHNICAL DATA
Height
Width
Depth
Weight
Weight with soap stone
Flue pipe outlet diameter
Nominal thermal output (EN 13240)
Maximum thermal capacity
Smallest heating capacity
2. IMPORTANT INFORMATION
The installation and operation information given here
is of general nature
standards, local and building regulations as well as
fire prevention laws must be observed during the
operation of the stove.
General safety instructions for
the operation of your stove
•
Thoroughly read the entire manual before
starting up your stove and observe the caution
notices.
•
Your heating unit may not be moved without
approved means of transport with sufficient load-
bearing capacity.
•
Your heating unit is not suitable to be used as a
stand or as a ladder.
•
Please keep in mind that your
stove's
surface
heats
considerably during operation. We
therefore recommend wearing a
safety mitten when operating your
stove.
•
Make your children aware of this particular
danger and keep them at a distance from the heating
unit whenever it is in operation.
•
Only burn approved fuels and materials listed in
the chapter "Clean Burning".
•
The burning or placing of flammable or explosive
materials, such as empty spray cans and such like
into the firebox as well as the storage of such
materials in the immediate vicinity of your heating unit
is strictly forbidden due the danger of explosion.
•
Do not wear loose or flammable clothing when
adding fuel to the fire.
.
1148 mm
546 mm
427 mm
152 kg
177 kg
150 mm
6 kW
8 kW
3,5 kW
. National and European
up
5
Room heating capacity (depending on
building insulation)
Exhaust values for multiple use of the chimney in
accordance with DIN 4705, Part 3 and for the
calculation of the chimney measurements in
accordance with DIN 4705, Part 2
Fluegas mass flow
Fluegas temperature
Minimum feed pressure
Nominal thermal output
•
Placing
non-heat-resistant
heating unit or in the vicinity of the heating unit is
forbidden.
•
Do not lay laundry onto the stove for drying.
Laundry hung up to dry must be kept at a safe
distance from the stove because of the danger of fire.
•
The woodstove KOKO 2.0 is not suitable for long
term heating.
•
During the operation of your heating unit it is
forbidden to use flammable or explosive materials in
the same or an adjacent room to the one in which
your heating unit is located
Setting up your stove
Required safety distances
distances – see name plate - in Fig. 2)
a > 1200 mm
b > 540 mm
c > 180 mm
(a – toward the front in the radiated area)
(b – to the side)
(c – to the back)
Make sure that the room in which the stove is set up
has at least one door or window into the outside or is
directly adjacent to such a room. Other fireplaces and
extractor hoods must not be operated in the same
.
room as the stove
english
65 - 165
m³
closed
4,43 g/s
closed
331 °C
closed
10 Pa
at 0.8 times
8 Pa
n. ther. outp.
objects
on
(Minimum
the