- ページ 9

ストーブ Austro Flamm Dexter 2.0 LのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Austro Flamm Dexter 2.0 L 11 ページ。

english
Heating in-between seasons
Heating the stove in between seasons, when the outside
temperatures are higher, the flue gases may not be able to
escape completely and this may lead to disturbances in the
chimney draught, especially if the temperatures are rising
suddenly. The stove has to be charged with less wood and
the primary air has to be increased so that the wood can
burn down faster (with visible flames) and thus the chimney
flue can stabilize.
4. THE MOST IMPORTANT SPARES—OVERVIEW
Gaskets
Description
Gasket hollow Ø 6x2260 mm
Gasket oval 16x8x2600 mm
Keramott
Description
Keramott baffle plate 2
Front Keramott base
Outside base Keramott corner
l/r
Inside base Keramott corner r/l
Rear Keramott base
Vertical Keramott outside
Vertical Keramott corner
Vertical Keramott rear
Keramott baffle plate 1
Grate
Other parts
Description
Door complete
Door handle
Door glass – short side
Door glass – long side
Stove varnish
Glass cleaner ½ litre
Accessories
You can obtain floor plates made of glass or steel, care products or the Heat Memory System for heat storage from your
certified dealer.
IMPORTANT:
Have defective parts replaced by your certified dealer. This will guarantee that your stove functions
properly and safely.
The fireplae must not be altered.
Maintenance
To clean the glass, please use a specialised product such as Thermohit glass cleaner. Lacquered surfaces are to be
cleaned only with a cloth (may be damp). Special cleaning agents should also be used for stainless steel surfaces.
Only gaskets in good order ensure the proper function of your stove!
Cleaning
The stove, flue outlets and smoke pipes should be cleaned and inspected for deposits every year – if necessary more often,
e.g. after the cleaning of the chimney. The chimney also has to be cleaned regularly by the chimneysweeper. Your
chimneysweeper will inform you of the necessary inspection intervals. An expert should inspect the stove annually.
Part
Part
reference
reference
No.
Dexter L
Dexter R
11
718183
12
718763
Part
Part
reference
reference
No.
Dexter L
Dexter R
1
720429
720474
2
720421
3
720422
720471
4
720423
720472
5
720427
6
720424
7
720425
8
720426
9
720428
720473
-
716408
Part
Part
number
number
No.
Dexter L
Dexter R
13
720430
720476
14
361089
15
720433
16
720432
720477
-
650002
-
640070
11
Chimney fire
A chimney fire may occur, due to sooting and deposits in the
chimney, if impropes or humid fuel is used. In case of a
chimney fire close all air inlets on the fireplace/chimney
immediately and call the fire brigade. Please have an expert
inspect your chimney for cracks and air-tightness after the
burning out of the chimney.
Dexter L
Keramott numbering = installation instructions!
Dexter
Dexter R