Section 3. PROGRAMMING THE SYSTEM
––––––––––––––––––– THE MECHANICS OF PROGRAMMING ––––––––––––––––
For actual program fields, refer to the programming form included at the center of this manual.
Entering Program Mode
Use one of the following methods:
•
Press both the [*] and [#] keys at the same time within 50 seconds after power is appled to the Control.
or
•
After power-up, enter the [Master Code] + 8 + 0 (default Master Code is 4110)
This method is disabled if you exit the program mode using *98 instead of *99. See "Exiting Program
Mode" later in this section.
Once you have entered program mode, data field *20 will be displayed (this is the first field in the system).
The system will now accept entries for field *20.
Programming a Data Field
↓ Field Number
20
Press [*] plus [Field No.] (e.g., *20), and then make the required entry. Note the following:
•
The keypad beeps three times when the data field has been completely programmed
•
The next Field No. is displayed. If you do not want to program this field, press [*] + the Field No. you
want to program.
•
If the number of digits that you need to enter in a data field is less than the maximum digits available
(e.g., the phone number field), enter the desired data, then press [*] + the next Field No. to be
programmed.
•
If you try to enter a non-existent field, the keypad will display EE or Entry Error. Simply re-enter [*]
plus a valid Field No.
Reviewing a Data Field
Press [#] plus [Field No. ]. Note the following:
•
Data will be displayed for that field number, entry by entry (a beep will be heard between entries and
three beeps after the last).
•
No changes will be accepted in this mode.
•
If you try to enter a non-existent field, the keypad will display EE or Entry Error. Simply re-enter [#]
plus a valid field number.
Erasing an Entry in a Data Field
Applies only to fields *40-*43, and *94.
Press [*] plus Field No. plus [*].
Downloading
*96 resets the Subscriber Account number and CSID in preparation for an initial download. If *97 was
entered previously, *96 must be entered last.
Clearing All Data Fields
*97 clears (zeros) all data fields. The Master Code will now be 0 0 0 0.
WARNING
Exiting Program Mode
*98 inhibits re-entry into the programming mode with the use of the Master Code.
*99 allows re-entry into the program mode using Master Code + 8 + 0.
DO NOT PRESS *97 IF ANY PROGRAMMING HAS BEEN DONE
PREVIOUSLY; DATA ALREADY PROGRAMMED INTO THE SYSTEM WILL
BE DELETED.
-8-