セキュリティシステム ADEMCO TI110B1のPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。ADEMCO TI110B1 18 ページ。 Gsm/pstn dual network burglar alarm system

negative electrodes. If you don't want to wired sensor, please don't take off the short
circuit wire.
(4) Extern Siren Wiring: there is an output terminal for external siren in the alarm panel. And
when wiring , please pay attention on the electrodes of siren and alarm panel to ensure
that you have a right wiring (Note: Red Line is positive and Black Line is negative)
(5) Telephone Wiring: please insert the crystal plug of the telecommunication line into the
"Telephone Line" interface of the alarm panel, and the telephone is inserted into the
"Telephone" interface.
(6)
"Alarm Tone" and "Alarm/Mute" optional: you are allowed to choose the alarm tone with
according to your real need. And it also supports "Alarm/Mute" optional. When the volume
switch is at the "Alarm" place, the alarm host will sound alarm in the field. And when it is
turn to the "Mute" place, the alarm host will not sound alarm but still sends the alarm
information out to the alarm receiving number
(7) Install Protective Cover: In order to protect from the wrong operation from others, please
install the protective cover and fasten screws on the side of the host where there are " Edit ","
Power ", "Alarm Volume " "Alarm/Mute " switches after installation and debugging.
Ⅵ.Technical Parameter:
GSM module: TC35i or TC35 Industrial-grade module
GSM frequency: EGSM 900 and GSM 1800
GSM module Voltage: 3.3—4.8V/ Working Current: 300mA (average)
GSM Consumption power: 2W (EGSM900); 1W (GSM1800)
SMS support format: AT, Text and PDU
Baud rate: 300bit/s –115kbit/s optional
Data transceiver mode: Asynchronous Serial interface (ITU-T RS232)
The 20-second prerecording alarm language segment through the digital recording chip
DTMF telephone dialing standard frequency: low frequency group: 697、770、852、941Hz;
high frequency group: 1209、1336、1477、1633H;Distortion: more than 1.5%
Level: the low frequency group:- 9dbm、3dm ; the high frequency group:-701 dbm、3dm
The distortion that cause by harmonic wave and intermodulation: at least 20db than the level
of fundamental wave, the signal limiting length:>40ms digit, discharge parameter quantity:
<15db
Exit delay: 000-255 seconds adjustable
Entry delay: 000-255 seconds adjustable
Power output: DC 12V, 100mA
Frequency: 315MHz/433MHz optional
External siren: 12V wired siren (110dB)
Working environment : temperature: 10℃~+45 ; relative humidity:≤95%
Power supply: AC220V±15%;DC 9.6V/600mA or 12V/600mA (optional)