BURGLARY ALARM SYSTEM OPERATION
(IF INSTALLED)
DISARMING THE SYSTEM
AND SILENCING BURGLARY ALARMS
(FOR AWAY, STAY, INSTANT, AND MAXIMUM ARMING)
PROCEDURE
1. Enter security code and press OFF [1].
The Ready message will be displayed
and the console will beep once to
confirm that the system is disarmed,
unless an alarm has occurred.
2. If an alarm has occurred, note the zone
descriptor displayed and repeat step 1
to restore the Ready message display.
If the message will not display, go to
the displayed protection zone and
remedy the fault (close windows, etc.).
If the fault cannot be remedied, notify
the alarm agency.
DURESS CODE
(WHEN FORCED TO DISARM/ARM UNDER THREAT)
Enter the pre-assigned duress code. The
system will disarm (or arm), but can silently
notify the central station of your situation, if
that service has been provided.
– 16 –
RESULT
Any alarm sounders will be silenced;
ALARM and zone descriptor (if displayed)
will clear only when the open sensor is
closed.
A fire alarm is indicated by a display of
both FIRE and the zone descriptor on the
Console. These will clear only when the
fire zone is again intact.
S e e
" S U M M A R Y
O F
A U D I B L E
NOTIFICATION" section for information
which will enable you to distinguish
between FIRE and BURGLARY alarm
sounds.
IMPORTANT
• This code is useful only when connected
to a central station.
BURGLARY ALARM SYSTEM OPERATION
(IF INSTALLED)
CHIME MODE
(THIS FEATURE IS FUNCTIONAL ONLY WHEN THE BURGLARY SYSTEM IS
DISARMED)
Your system can be set to alert you to the
opening of a door or window while it is
disarmed by using CHIME mode. When
activated, three tones will sound at the
Console whenever a door or window is
opened, and the Not Ready message will
be displayed. Pressing the READY [*] key
will display the open protection points.
Note that Chime mode can be activated
only when the system is Disarmed.
TESTING THE BURGLARY SYSTEM
(TO BE CONDUCTED WEEKLY)
This feature can be used by your installer or by the master or manager user. Use this
test to check that sensors on all burglary and non-fire emergency zones are
operating properly. Note: If you fault a fire zone, you will cause a fire alarm!
1. Disarm the system.
2. Enter a master or manager code and
press the TEST [5] key.
3. The external burglary sounders will
sound for 3 seconds to indicate that the
test has started.
The console will
display "BURGLARY WALK TEST IN
PROGRESS" and will beep every 15
seconds while the test remains active.
4. Open and close each protected door
and window in turn.
Each action
should produce three beeps from the
Console, and the identification of each
protection point should appear on the
display.
To turn Chime Mode on, enter the
security code and press the CHIME [9]
key. The CHIME MODE ON message will
appear for about two seconds then
disappear. To display this message again
(to determine whether chime mode is on or
off), simply press and hold down the
CHIME key for 5 seconds.
To turn Chime Mode off, enter the
security code and press the CHIME [9] key
again. The C HIME MODE OFF message
will appear for about two seconds then
disappear.
5. Walk in front of any interior motion
detectors (if used). Listen for three
beeps
as the detector
senses
movement. The identification of the
detector should appear when it is
activated.
6. When all protection points have been
checked, there should be no zone
identification numbers displayed. If a
problem is experienced with any
protection point (no confirming beeps,
no display), CALL FOR SERVICE
IMMEDIATELY.
7. Turn off Burglary Walk Test mode by
entering any security code and
pressing the OFF [1] key.
– 17 –