- ページ 9
DCドライブ AutomationDirect Leadshine EM556SのPDF クイック・スタート・マニュアルをオンラインで閲覧またはダウンロードできます。AutomationDirect Leadshine EM556S 17 ページ。 Stepper drives
DM322E Connection to a Sinking Output Controller
Controller
VCC
PUL
DIR
ENABLE
DM322E Connection to Differential Control Signal
Controller
VCC
PUL+
PUL-
DIR+
DIR-
ENA+
ENA-
Note: Although the controller has a pair of
differential outputs (+,-), the + output is not
used in this configuration with the DM322E.
DIP Switch Settings
Dynamic Current Configurations
Peak Current (A)
0.3
0.5
0.7
1.0
1.3
1.6
1.9
2.2
Leadshine Stepper Drives Quick Start Guide – First Edition – 11/04/2019
R=0 if VCC=5V
R=1K(Power>0.125W) if VCC=12V
R=2K(Power>0.125W) if VCC=24V
R must be connected to control signal terminal
R
R
R
Power Supply
Stepping
Motor
R=0 if VCC=5V
R=1K(Power>0.125W) if VCC=12V
R=2K(Power>0.125W) if VCC=24V
R must be connected to control signal terminal
R
R
R
Power Supply
Stepping
Motor
DM322E Current Configuration
RMS Current (A)
0.21
0.35
0.49
0.71
0.92
1.13
1.34
1.56
Leadshine Stepper Drives Quick Start Guide
DM322E Driver
270 Ω
OPTO
PUL
270 Ω
DIR
270 Ω
ENA
VDC
GND
A+
A-
B+
B-
DM322E Driver
270Ω
OPTO
PUL
270 Ω
DIR
270 Ω
ENA
VDC
GND
A+
A-
B+
B-
SW1
SW2
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
SW3
ON
ON
ON
ON
OFF
OFF
OFF
OFF
Page 9 of 17