- ページ 10

冷凍庫 FRIGOGLASS Impulse Chest CoolerのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。FRIGOGLASS Impulse Chest Cooler 14 ページ。

FRIGOGLASS Impulse Chest Cooler ユーザーマニュアル
ENG
FAULT
POSSIBLE REASONS
The thermostat setting is not
correct.
The ICM has recently been
reloaded with warm products. It
takes 8-16 hours to cool them
down.
The cooler
The ICM is loaded in such a way
does not cool
that the air circulation in the
enough. The
interior is getting blocked.
products are
warm.
The door does not seal properly.
Leakage in the cooling system.
For this particular ice cold
merchandiser, a powerful
mechanism is needed and
consequently a certain amount
of noise cannot be avoided.
The ICM
sometimes
Intense metallic noise.
makes noise.
Inclined or curved floor.
The drainage hole for the
There is water
condensate water is blocked.
on the floor.
There is a leakage in the tray.
The lights don't
The fluorescent tubes or ballast
work.
or starter are out of order.
The supply
cord is
damaged.
If after all the above-mentioned checks the problem with your ICM remains, contact
the customer service department of your supplier and provide the following
information:
x
Type of ICM
x
Serial number of the ICM
x
Brief description of the problem / observation
HANDLING
Rotate the thermostat knob
clockwise.
Preferably, reload the ICM
before night closing.
Load the ICM according to the
standards you have been
provided with by the company.
Repair the doors for proper
closing (this type of repair
should be performed by an
authorised technician).
Repair the leakage (this type of
repair should be performed by
an authorized technician).
Ice Cold Merchandisers are
of dynamic type, according
to the specifications that the
company is offering.
Call a Service technician.
Level the ICM properly by
adjusting its feet. Placing a spirit
level on the top of the ICM will
assist you in leveling it.
Unblock the drainage hole.
Call a Service technician.
Call a Service technician.
If the supply cord is damaged, it
must be replaced by the
manufacturer, its service
provider or similarly qualified
persons in order to avoid a
hazard.