- ページ 4
エアクリーナー AirGorilla PCO/UV N-DuctのPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。AirGorilla PCO/UV N-Duct 6 ページ。
AirGorilla PCO/UV N-Duct にも: インストーラー・マニュアル (8 ページ)
OPERATIONAL DISPLAY PANEL
AirGorilla' s innovative Display Panel reports with large, bright LEDs the operation status of all
the important functions of the unit.
ULTRAVIOLET LAMP LIFE
Like all light bulbs, UV lamps have a life span. Unlike regular light bulbs, however, UV lamps
loose their effectiveness over time. Typically, after 9000 hours of use (approximately 1 yr.),
the lamps do not produce enough ultraviolet germicidal irradiation to be effective. However,
even after this time, the lamps usually do not burn out, but stay lit. This is often confusing
to owners, but the lamps simply no longer produce the intensity necessary to be effective in
improving or maintaining indoor air quality and must be replaced. It should also be noted
that some ultraviolet lamps burn out prematurely and do not last the full 9000 guaranteed
hours. AirGorilla' s visual and audible reminders of when the UV lamps need to be replaced
(or if they have burned out) help ensure you are receiving the full benefit and effectiveness
of the PCO/UV N-Duct's™ advanced air cleaning technologies.
AUDIBLE ALERT – the PCO/UV N-Duct unit is often installed in
areas not readily visible to the owner and therefore the Replace
Lamp LED may not be seen when lit. When the UV lamps need to
be replaced, an audible alert will also be sounded (a continuous
beep) to notify you of the need to replace the lamp(s).
3
Replace #1 UV Lamp – top UV
lamp needs to be replaced
#1 UV Lamp On – top UV lamp
is lit and operational
POWER ON – indicates the unit is
receiving electrical power
#2 UV Lamp On– bottom UV
lamp is lit and operational
Replace #2 UV Lamp – bottom
UV lamp needs to be replaced