- ページ 5

エアーコンプレッサー ALITA AL-30のPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。ALITA AL-30 12 ページ。 Linear air compressors

ALITA AL-30 取扱説明書
For outdoor installations, shaded area that shelters from excessive weathering
is ideal. Do not allow pump to swelter under intense sun and avoid places with
excessive dust or debris.
The ambient operating temperature for this pump is between 5°C (41°F) and
40°C (104°F). Operation of pump in temperature outside of the recommended
temperature range may result in malfunction or severely shorten the pump life.

PIPE SIZING

Utilize air tubing or pipes that are equal or larger than the pump discharge port.
Matching pipe fittings should be used to reduce frictional losses. Incorrect pipe
sizing can cause unsatisfactory performance.
When selecting or constructing an air manifold, the number of outlet fittings and
their orifice size must be considered carefully to minimize frictional losses. Do
not block or restrict pump discharge for extended periods. Install a bleed valve
to vent any excess air volume and attach an air diffuser as silencer or muffler.

ELECTRICAL SAFETY

Form a drip loop with the power cord before connecting to the electrical
terminal. Drip loops can prevent water from traveling down the cord and
entering the power connection.
In the event of an electrical short circuit, grounding reduces the risk of electric
shock by providing an escape wire for the electric current. This pump is
equipped with a cord having a grounding wire with an appropriate grounding
plug. The plug must be plugged into an electrical terminal that is properly
installed and grounded in accordance with all local codes and ordinances. Do
not modify the plug provided; if it does not fit the outlet, have the proper outlet
installed by a qualified electrician.
Electrical Outlet with GFCI
Connect the pump only to a terminal with Ground
Fault Circuit Interrupter (GFCI) installed. This
device should serve to interrupt the flow of electric
current in the event of ground faults (electrical
current that unintentionally flows to ground). Check
proper operation of GFCI every month, and replace
faulty GFCI immediately.
Plug with
grounding pin

EXTENSION CORD

If an extension cord is required, use only a 3-wire extension cord that has a 3-
blade grounding plug, and a 3-slot receptacle that accepts the plug on the
pump. Be sure to use one heavy enough to carry the current the pump draws.
For lengths less than 50 feet, No. 16/3 AWG extension cord shall be used. An
undersized cord can result in a drop in line voltage, loss of power and
overheating. Replace any damaged extension cord immediately.
- 4 -