Fault finding table

Trouble
Burner does not light.
Burner extinguishes after
lighting
Flames leave the
-
confines of
the burner,
-
or are
sooting, - or a blue
cloud is under the
reflector
The burner is only partly
glowing
The burner makes a lot
of noise after ignition or
after several minutes
The burner do not work
at minimum position
Heater will not attain the
desired temperature
Version: April 2016
Action
Check if gas valve of the gas cylinder or gas line is open
Check if gas cylinder is empty
First ignition will take up to 60 or more seconds before gas is available
Check if the injector is blocked
Check if the gas pressure/gas quality is identical to the pressure
indicated on the data plate
Keep button safety device pressed for a longer period (up till 25
seconds)
Check if the thermocouple is connected properly to the gas safety
device
Check if the thermocouple tip is 8mm under the bottom plate (27 or 28)
Thermocouple or magnetic coil of the safety device is broken.
Gas pressure lower than minimum requested
Heater not suspended at 15 degrees angle
Gas pressure is too high. Check the gas pressure with the data
plate
Check if the gas pressure regulator is broken.
Wrong gas is used. Check data plate for the correct gas supply
Venturi/air inlet is blocked/dirty
Valve dual injection model DI is leaking
Check the size of the venturi and injector with the table
Not enough fresh air available due to mounting situation
Air filter is dirty
Heater not suspended at 15 degrees angle
Small o-ring (47) DI is missing or leaking
Wrong gas or pressure is used. Check data plate with the gas supply
Check if the injector or venturi are blocked or dirty
Check the injector and venture size with the table
Check if pipe sizes or gas hoses have sufficient capacity
Check the setting of the thermostat
Valve dual injection model DI is blocked
Wrong gas is used. Check data plate with the gas supply
Check if the inner globe is broken or damaged so the flame burns
inside the venturi tube
Gas pressure is not correct. Check the gas pressure with the data plate
Wrong gas is used. Check data plate for the correct gas supply
Check the size of the venturi and injector with the table
Sensor or wire thermostat TH is broken
Thermostat TH valve adjusting mechanism is blocked
By-pass hole thermostat TH or solenoid valve MK is blocked
Injector (partly) blocked
Centre hole dual injector DI is blocked
Check if the thermocouple tip is 8mm under the bottom plate (27 or 28)
There is insufficient heat in the building for heat loss (i.e., not enough
brooders).
The thermostat TH sensing bulb is incorrectly placed
The thermostat TH is out of calibration or broken
The solenoid valve MK is not functioning
One of the two holes of the dual injector DI is blocked
partly blocked
13
Injector
manual number: 0009 0440EN