- ページ 7
ノートパソコン Fujitsu Lifebook C2310のPDF バイオマニュアルをオンラインで閲覧またはダウンロードできます。Fujitsu Lifebook C2310 31 ページ。 Lifebook c series
Fujitsu Lifebook C2310 にも: ソフトウェアマニュアル (39 ページ)
Table 2: Fields, Options and Defaults for the Primary Master Submenu of the Main Menu
Menu Field
Options
Sectors:
• A number
between
0 and 63
Maximum
• Display only
Capacity:
LBA Format (Logical Block Addressing)
Total
–—
Sectors:
Maximum
–—
Capacity
Multi-
• Disabled
• 2 Sectors
Sector Trans-
• 4 Sectors
fers:
• 8 Sectors
• 16 Sectors
LBA Mode
• Disabled
• Enabled
Control:
Transfer
• Standard
• Fast PIO 1
Mode:
• Fast PIO 2
• Fast PIO 3
• Fast PIO 4
• Multiword
DMA 1
• Multiword
DMA 2
Ultra DMA
• Disabled
• Mode 0
Mode:
• Mode 1
• Mode 2
• Mode 3
• Mode 4
• Mode 5
A bootable CD-ROM may have a floppy disk format or a hard drive format. When the bootable CD-ROM is used,
the drive allocations change automatically without changing the BIOS setup. If a floppy disk format CD-ROM is
used, the CD-ROM becomes Drive A. The CD-ROM will only take Drive C: (hard drive format) if the internal hard
drive is not present or is disabled. The bootable CD-ROM can never use a C: designation if a formatted internal
hard drive is present, since the C: designator is always reserved for the internal hard drive. The boot sequence
ignores the new drive designations, but your application software will use the new designations.
Be careful of the operating environment when booting from a CD-ROM or you may overwrite files by mistake.
Default
Description
–—
This appears only when Hard Disk is selected. When it is selected, you can
change the value. This field is incremented by pressing the [Spacebar]. This
field is decremented by pressing the [-] key. The field can also be changed by
typing in the number.
–—
Displays the maximum capacity of the drive calculated from the
parameters of the hard disk when Hard Disk is selected.
–—
The total number of sectors on your hard disk.
–—
The maximum capacity of your hard disk.
[16 Sectors]
This option cannot be changed when Auto is selected. Specify the number of
sectors per block for multiple sector transfer.
[Enabled]
Enables or disables Logical Block Addressing in place of Cylinder, Head, Sector
addressing. This can't be changed when Auto is selected.
[Multiword
Selects the method for moving data to/from the drive. Autotype the drive to
DMA 2]
select the optimum transfer mode. This option cannot be changed when
Auto is selected.
[Disabled]
Selects the method for moving data to/from the drive. Autotype the drive to
select the optimum transfer mode. This option cannot be changed when
Auto is selected.
M a i n M e n u
7