調理器 Indesit K3C36/GのPDF 取付・使用説明書をオンラインで閲覧またはダウンロードできます。Indesit K3C36/G 17 ページ。 Cooker with electric ventilated oven and ceramic hob

The following instructions should be read by a qualified technician
to ensure that the appliance is installed, regulated and technically
serviced correctly in compliance with current regulations.
Important: disconnect the cooker from the electricity when
making any adjustement, maintenance operation, etc.
Positioning
The appliance can be installed next to furniture units which are
no taller than the top of the cooker hob. For proper installation of
the cooker, the following precautions must be taken:
a) Kitchen cabinets installed next to the cooker that are taller
than the top of the hob must be situated at least 200 mm
from the edge of the hob.
b) Hoods must be installed according to the requirements in
the installation manual for the hoods themselves and in any
case at a minimum distance of 650 mm.
c) Place the wall cabinets adjacent to the hood at a minimum
height of 420 mm from the hob (see figure).
d) Should the cooker be installed beneath a wall cabinet, the
latter should be situated at least 700 mm (millimetres) away
from the hob, as shown in the figure.
e) the cut-out for the cooker cabinet should have the dimensions
indicated in the figure.
Min.
Levelling your appliance (only on a few models)
Your cooker is supplied with feet for levelling the appliance. If
necessary, these feet can be screwed into the housings in the
corners of the cooker base (Fig. A).
Mounting the legs (only on a few models)
Press-fit legs are supplied which fit under the base of your cooker
(Fig. B).
Fig. A
Electrical connection
Electric cookers come without a power supply cable. The cooker
is designed to operate on an electricity supply which conforms
to the electrical data shown on the Rating Plate. The cooker can
be connected to the mains only after removing the back panel of
the cooker itself with a screwdriver.

Installation

HOOD
600
mm.
Fig. B
N.B.: the following installation procedure must be carried out by
a qualified electrician. The electrical installation must comply with
the IEE Regulations, Building & local By-Lays.
For the installation of the feeding cable carry out the following
operations:
Unscrew screw "V" (see fig. C)
Pull and open the junction blok lid
Important: the wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow
Blue
Brown
As the colours of the wires in the mains lead may not correspond
with the coloured markings identifying the terminals in your plug,
proceed as follows:
Green & Yellow wire to terminal marked "E" or
Green or Green & Yellow.
Brown wire to terminal marked "L" or coloured Red.
Blue wire to terminal marked "N" or coloured Black (see fig. D).
fix the feeding cable in the special cable stop and close the
cover.
N.B.: the power supply cable must have these minimum
requirements:
Type:
H05RR-F
2
Section: 3x4 mm
V
Fig. C
Connecting the supply cable to the mains
WARNINGS: THIS APPLIANCE MUST BE EARTHED.
Important: The cooker must be connected to the mains by a
switched (double pole) cooker outlet correctly fused with a
capacity appropriate to that shown on the cooker Rating Plate.
All electrical wiring from the consumer unit to the cooker, via the
switched double pole cooker outlet, must be of an acceptable
type and current rating as above.
Note: the supply cable must be positioned so that it never reaches
at any point a temperature 50°C higher than the room tempera-
ture. The cable must be routed away from the rear vents.
4
Earth
Neutral
Live
or coloured
Fig. D
HOT PARTS