- ページ 8

冷凍庫 AEG Table Top FreezersのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。AEG Table Top Freezers 14 ページ。 Table top freezers
AEG Table Top Freezers にも: 取扱説明書 (16 ページ)

AEG Table Top Freezers 取扱説明書
GB

Your freezer needs air

Fig. 4
The cooling unit is designed for maintenance-free
operation.
What it should never lack is good ventilation. Air is
drawn in under the door, through the ventilation slits
in the plinth, through the gap between the appli-
ance and the wall, and passes out through the air
outlet
grille on top. Never obstruct these openings.
If the freezer is installed under a continuous work-
surface, an air outlet must be provided of at least
2
200 cm
and a grille (C/D) provided to suit the
design of the worktop (Fig. 4 ).
The cut surface of the worktop (E) must be painted
in order to prevent moisture entering and distorting
it.
The minimum clearance between the appliance and
the wall should be at least 30 mm, and should be
checked before the air-outlet grille is fitted.
Special accessories:
C Air outlet grille, brown (E-No. 621 814 002)
D Air outlet grille, white (E-No. 621 825 004).

Removing the worktop

Fig. 5
After removal of the worktop of your table-top
freezer the appliance can be installed under a
continuous worktop.
P ro c e e d a s d e s c r i b e d h e re : U n s c re w t h e
cross-head screws (F) on the right and the left.
Lift the worktop slightly, move it about 5 mm
towards the rear, and lift it out upwards (G).
Unscrew the worktop holders (H) and keep them in
a safe place.
Mounting under a continuous
worktop
Fig. 6
If the appliance is to be installed under a continuous
worktop, it needs to be fastened in place on the
right and the left with a fastening screw (F) which
passes through the elongated hole of the door
mounting. The mounting screws of the removed
worktop can be used for this purpose.
16

Changing over the door hinges

Figs. 7 to 9a
Before connecting your freezer to the power supply,
you should check whether the door must be
rehinged to open from the right (as delivered) to
opening from the left, if this is required by the instal-
lation position or for ease of operation.
1. Tilt the appliance backwards.
2. Pull the plinth panel off from in front.
3. Unscrew the door bearing (K) and take the door
bearing (1) off downwards out of the pivot hole.
4. Open the door slightly and take it off down-
wards. Place it aside and protect it against dam-
age.
5. Unscrew the upper swivel pin (2) and screw it
into place on the other side again.
6. Fit the door into the upper swivel pin (2) and
close it.
7. Fit the door mounting pin of the door mounting
(1) into the left-hand pivot hole and screw the
door mounting in with the screws (K).
8. Transfer the separate fitment (L),of the plinth
panel from left to right and press the plinth panel
back into the panel holders.
9. Unscrew the handle. Refit it on the opposite side
after having pierced the plugs with a punch.
Cover the holes left open with the plugs con-