3. Remove the laundry.
4. Close the appliance door.
Possible causes of unsatisfactory drying
results:
• Inadequate default dryness level
settings. See chapter
default dryness level
• Room temperature is too low or too
high. Optimal room temperature is
between 18°-25°C.
8.12 Drum light on

9. HINTS AND TIPS

9.1 Ecological hints
• Spin the laundry well before drying.
• Do not exceed the load sizes which
are specified in the programmes
chapter.
• Clean the filter after each drying
cycle.
• Do not use fabric softener to wash
and then dry. In the tumble dryer
laundry becomes soft automatically.
• The water from the water container
can be used to iron the clothes. You
must first filter the water to eliminate
remaining textile fibres (simple coffee
filter is suitable).
• Always keep the airflow slots at the
bottom of the appliance clear.
• Make sure there is good airflow where
the appliance is to be installed.
9.2 Adjustment of default
dryness level
To change the default dryness level:
1. Turn the appliance on.
2. Select 1 of the available
programmes.
3. Touch and hold down the Time Dry
and + Anti Crease buttons at the
same time.
Adjustment of
Touch and hold down Silent button by
around 3 seconds.
The light inside the drum is on.
8.13 Possible causes of
unsatisfactory drying results:
• The filter is clogged. Clogged filter
makes drying inefficient.
• The airflow slots are clogged.
• The humidity sensor is dirty.
• The drum is dirty.
• Inadequate default dryness level
settings. See chapter
default dryness level
• Room temperature is too low or too
high. Optimal room temperature is
between 18°-25°C.
One of the symbols appears on the
display:
- Maximum dryness
- Extra dryness
- Standard dryness
4. Touch the Start/Pause button
repeatedly until you reach the
desired dryness level.
Dryness
level
Maximum
dryness
Extra dry‐
ness
Standard
dryness
5. To memorise the setting touch and
hold down the Time Dry and + Anti
Crease buttons at the same time for
approximately 2 seconds.
Adjustment of
Display symbol