Product Manual Omnia Hand Dryer
ADJUSTMENTS
MOTOR, DETECTION DISTANCE ADJUSTMENT AND HEATING ELEMENT SWITCHING.
The hand dryer has means to manually adjust the distance for detecting hands and the speed of the
drying air.
The adjustments can be made by moving the respective cursors of the two linear potentiometers, as
shown in figure.
The "motor unit" incorporates a heating element which could be connected or disconnected by the
'ON/OFF' switch.
HOW TO USE
The hand dryer starts automatically when the hands are placed near the LEDs detection zone, which
is just next to the air outlet. Hand detection and the ensuring starting of the machine is based on
emission-reflection-reception of an IR light beam coming from the sensors. The detection distance is
between 120 and 150 mm approximately. (4.72 – 5.9").
MAINTENANCE
Adequate cleaning of the hand dryer will extend its useful life. It is recommended to remove any dust ac-
cumulated inside the hand dryer at least once a year.
Disconnect the hand dryer from the power supply.
Clean away the dust and remove any dirt accumulated inside the hand dryer, using a dry cloth or a
soft brush.
Clean from the air input to inside the motor (upper part of the nozzle) preventing dust or dirt falling
inside the turbine-motor assembly.
• Carefully clean the dust away from around the electronic circuit located inside its box- type housing.
6 of 7
Product Manual Omnia Hand Dryer
Carry out this operation taking maximum care not to damage any component of the electronic circuit.
Clean the casing using a damp cloth moistened in a solution of neutral soap and water. After cleaning
the entire surface, to rinse the soap from the casing using another cloth moistened in water and dry
using a dry cloth.
Close the hand dryer by assembling the casing once more, tightening the screws that fix the casing to
the base and connect to the power grid.
Start the hand dryer up 2 or 3 times in a row to ensure that all remaining dust is extracted.
Air filter and odor-neutralizing balls:
Replace the old filter by pulling from the lateral flaps, as shown on picture.