- ページ 12
浄水器 Aqua Exclusive C-30 PROのPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。Aqua Exclusive C-30 PRO 18 ページ。 Drum filter
Aqua Exclusive C-30 PRO にも: オーナーズマニュアル (20 ページ)
Aqua Exclusive
1
2
3
Figure 7: C-30 PRO with rinse pump
1. Rinse Pump Filter outlet 4" (110mm)
2. Hose/PVC pipe to Rinse Pump Inlet
3. PVC Reducer ring
4. Spray Bar
5. Hose/PVC pipe from Rinse Pump Outlet to Spray Bar
6. Build-in UV-System
7. Drum Motor
8. Filter Outlet 4" (110mm)
9. Flexible Rubber Tee Coupling 4" (110mm)
•
It is important, however, that a high-pressure hose/PVC pipe is used for this purpose.
•
The pump generates a pressure of 3 bar. Pressure peaks of 4 bar may occur during start-
up. Therefore do not use sewer & drain PVC.
•
The high-pressure pump itself must be placed in a moisture-free location below the water
level.
•
TIP: Place a ball valve between the output and the high pressure pump.
1.
2. Connect the output of the tee to the high-pressure pump (2) and the high pressure pump
to the spray tube (5).
10
Rinse Pump
C-25 EVO OWNER'S MANUAL
4
5
6
7
8
9