- ページ 12
スイッチ AVProConnect AC-SW411-AUHDのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。AVProConnect AC-SW411-AUHD 19 ページ。 18 gbps 4x1+1 switcher with 100 meter hdbaset receiver
RS-232 and Ethernet Commands and Syntax
Note: Commands are the same in both IP and RS-232 except you need to preface all RS-232
command with the "@" sign. Do not use any brackets like ("</>")
For selecting input:
insel: HDMI Input Selection
usage example: insel <1|2|3|4>
For getting device status:
st: Get Device Status
usage example: st
To power the device on or off:
power: power AVP-X411 on/off
usage example: power <on|off>
NOTE:
The RS232 port is also connected to the HDBT extender, and available on the remote
end. We allow a control system to communicate both with the device on the other end as well as the
SW411 directly. To do this, the commands above must be prefixed with either @sw411 or
@<hostname> where <hostname> is the name configured through the web page (defaults to sw411-
XXXX).
Response Structure:
<@hostname> <sp> <parameter> <sp>... <parameter> <sp> <end of
response>
<@hostname> = indicates the device initiating the response
<sp> = space, ASCII 0x20
<parameter> = command-specific number of parameters, each followed by a
space 0x20 [hex] <end of response> = newline char \n, ASCII 0xA [hex]
For example:
@sw411 insel 3
@sw411-0000 insel 2
AVProConnect ~ 3518 N Casco Ave. Sioux Falls, SD 57104 ~ 1.877.886.5112 ~ +1.605.274.6055 ~ [email protected]
To print a summary of commands:
help: Responds with command list
usage example: help
To get a report of system up time:
uptime: Responds with System uptime
usage example: uptime
To check the firmware revision:
version: Responds with Firmware Version
usage example: version
pg. 12