- ページ 21

換気フード Miele DA 396-5のPDF 操作およびインストール手順をオンラインで閲覧またはダウンロードできます。Miele DA 396-5 36 ページ。
Miele DA 396-5 にも: 操作およびインストール手順 (36 ページ)

Miele DA 396-5 操作およびインストール手順
Extraction
Recirculation
Ventilation grille positioned at the top
for recirculation
,
(
is not required for recirculation
mode cooker hoods)
The shaded area represents the wall or
ceiling area for the vent cut-out, for
fitting the connection socket and on
...EXT models for feeding the
connection cable through to the
external motor.
For recirculation mode, only a
connection socket needs to be fitted.
Connection for air extraction
C 150 mm, or C 125 mm with reducing
collar.
Appliance dimensions
Safety distance between hob and
cooker hood (S)
When planning the installation height
of your cooker hood, the minimum
safety distances between the top of
a cooker or hob and the bottom of
the cooker hood are as follows,
unless a greater distance is
specified by the manufacturer of
your cooking appliance:
450 mm (GB), 600 mm (AU, NZ)
above electric hobs and cookers,
650 mm above an open grill or deep
fat fryer,
650 mm above gas hobs and
cookers.
If this cooker hood is installed above
a Miele Wok CS 1028 CombiSet
appliance, a minimum safety
distance of 760 mm must be
maintained between the burner and
the lower edge of the cooker hood.
See "Warning and Safety" instructions
for further information.
– When deciding on the safety
distance between the hob and
cooker hood, please note that a
distance of 650 mm above electric
cookers/hobs may be preferable to
give more working space under the
hood.
– Account should also be taken of the
height of the person who will be
using the hood most often. The
person should have sufficient space
to work comfortably at the hob, and
also be able to reach the hood
controls with ease.
21