- ページ 8
浄水器 Aquasana AQ-UV-L330CのPDF オーナーズマニュアルをオンラインで閲覧またはダウンロードできます。Aquasana AQ-UV-L330C 20 ページ。 Whole house uv filter
INSTALLATION STEPS
6
1
Installation Checks and Options
1. To facilitate future lamp replacements, ensure there is enough space
at the UV Lamp connector end to safely remove the UV Lamp
and/or Quartz Sleeve.
NOTE: Leave at least an additional UV Reactor length to facilitate UV
Lamp and Sleeve removal.
2. The Controller will require a ground fault circuit interrupter (GFCI or GFI)
outlet and should be mounted beside or above the UV Reactor.
3. For water supplies where the maximum flow rate is unknown, a flow
restrictor is recommended so that the rated flow of your particular
Aquasana system is not exceeded. The flow restrictor should be
installed on the outlet port of the UV Reactor.
4. The UV Reactor can be installed
either horizontally or vertically
using the clamp provided.
Vertical installation is the preferred
method with the inlet at the bottom
(UV Lamp connection at the top)
as it allows any air that may be in
the lines to be easily purged
from the system.
1
2
Vertical
(preferred)
Horizontal