S A F E T Y N O T E S
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and
tested as per the applicable standards.
⁄ The plumbing codes applicable in the respective
countries must be observed.
T E C H N I C A L D A T A
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
⁄ Safety against backflow
⁄ The product is exclusively designed for drinking water!
F A U L T
⁄ Mixer stiff
⁄ Mixer dripping
⁄ Water escaping at the threaded base ⁄ connection hoses not completely
⁄ Hot water temperature too low
A S S E M B L Y (see page 05)
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
65°C
max. 70°C ⁄ 4 min
C A U S E
⁄ Cartridge defective, calcified
⁄ Cartridge defective
screwed into basic body
⁄ O-ring at the connection hose defec-
tive.
⁄ Hot water limiter incorrectly set
S Y M B O L D E S C R I P T I O N
Do not use silicone containing acetic acid!
A D J U S T M E N T (see page 10)
To adjust the hot water limiter. Using a hot water
limiter in combination with a continuous flow
water heater is not recommended.
D I M E N S I O N S (see page 04)
F L O W D I A G R A M ( s ee page 04)
C L E A N I N G (see page 12)
M A I N T E N A N C E (see page 12)
The check valves must be checked regularly
according to EN 806-5 in accordance with
national or regional regulations (at least once a
year).
S P A R E PA R T S ( s ee page 13)
O P E R A T I O N (see page 11)
Hansgrohe recommends not to use as drinking
water the first half liter of water drawn in the
morning or after a prolonged period of non-use.
R E M E D Y
⁄ Exchange cartridge
⁄ Exchange cartridge
⁄ Tighten connection hoses by hand
⁄ Exchange O-ring
⁄ Set hot water limiter