- ページ 11

ホブ Siemens ED851FQ15EのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Siemens ED851FQ15E 24 ページ。 Induction hob with integrated ventilation system

9  Hood control
You can use the hood control to control the highly effi-
cient air extraction system that is integrated in the
cooking surface.
9.1 Manual ventilation control
You can control the ventilation setting manually.
Note: Using tall items of cookware may prevent the ex-
traction system from working at optimum power. You
can improve the extraction power by placing the lid on
the cookware at an angle.
Activating the manual ventilation control
1.
Touch
​ ⁠ .
The ventilation system starts at the preset perform-
ance level.
2.
Within the next 10 seconds, select the required per-
formance level in the settings area.
The set performance level lights up.
3.
Touch
​ ⁠ to confirm the setting.
a The ventilation system is activated.
Changing or deactivating manual ventilation
control
1.
Touch
​ ⁠ .
2.
Select the required performance level in the settings
area or set it to ​ ⁠ .
9.2 Intensive ventilation setting
The ventilation system has two intensive modes. If you
activate the intensive settings, the ventilation system
works at maximum output for a short time.
Activating the intensive ventilation setting
1.
Touch
​ ⁠ .
2.
Select the required intensive setting:
Intensive setting I: Select the performance level
​ ⁠ and then touch
setting is activated.
Intensive setting II : Touch
play lights up. The setting is activated.
Note: After approx. eight minutes, the appliance auto-
matically switches back to performance level  ​ ⁠ .
10  combiZone
It allows two cooking zones of the same size to be
combined, with the same power level being switched
on in both. This is intended in particular for cooking
with long cookware.
This function allows you to cook with one item of cook-
ware that occupies one cooking zone and that can be
moved from one zone to another for increased conveni-
ence. In this case, the two zones also retain the same
power level and the same settings.
​ ⁠ . The ​ ⁠ display lights up. The
​ ⁠ again. The
Changing or deactivating the intensive
ventilation setting
1.
Touch
2.
Select the required performance level in the settings
area or set it to ​ ⁠ .
9.3 Automatic start for the ventilation
system
If you select a power level for a cooking zone, the auto-
matic start switches on.
The ventilation system switches on at a power level in
accordance with the respective power level for the
cooking zones. You can find out how to change this
setting in section
→ "Basic settings", Page 14.
9.4 Ventilation run-on function
The run-on function leaves the ventilation system run-
ning for a few minutes after the hob has been switched
off. This allows you to remove any cooking fumes that
remain. The ventilation system then automatically
switches off.
Activating the fan run-on
As standard, the run-on time is activated with a max-
imum switch-off time.
You can find out how to change this setting in section
→ "Basic settings", Page 14.
Note: The run-on function only switches on if at least
one cooking zone has been switched on for at least
one minute.
Deactivating the fan run-on
Manually
To deactivate the function, touch  ​ ⁠ .
Automatically
The appliance deactivates the run-on function when:
​ ⁠ dis-
¡ The run-on time has elapsed.
¡ You switch the appliance on again.
10.1 Positioning the cookware
Use cookware that fits into the cooking zones.
​ ⁠ .
Hood control en
11