Model:
SP3
Subject:
SCU ROM Modification
From:
QAC Field Information Dept.
Classification:
This bulletin describes the software modifications for the SCU board.
NOTE: This software modification has been released before the previous modification
bulletin (RTB No.6). The following part numbers are not the latest versions. Please
refer to RTB No.6 for the latest version.
This technical bulletin is issued only for modification history information.
Two ROM chips [Copy1 and MF Shell (Copy2)] have been changed for this modification.
This software version had been included in SP3 machines from December 97 production.
Engineering Change Request
Lanier has requested us to change the
default setting of the double counting for
A3/DLT size from No to Yes (SP 5104).
Lanier has requested us to change the
default setting of the paper length of the 8.5"
width paper from 11" to 14" (SP 1900).
T
echnical
Troubleshooting
Mechanical
Paper path
Other (
)
B
ulletin
Date:
31-Mar-98
Prepared by:
Part information
Electrical
Transmit/receive
Countermeasure
Modified software.
If Lanier is selected as the OEM code
setting, this default setting will be used.
Modified software.
If Lanier is selected as the OEM code
setting, this default setting will be used.
PAGE: 1/2
No:
13
A.Tokoyama
Action required
Service manual revision
Retrofit information