Checking the Installation
Checking the RSP7000 Installation
Use the following information to verify that the RSP7000 operates properly. When you turn the
system power back on, verify that the system boots and resumes normal operation.
Perform the following steps to verify that the RSP7000 is installed and functioning properly:
Step 1
Step 2
Step 3
Step 4
Step 5
When you have verified all the conditions in Steps 2 through 5, the installation is complete.
If you replaced the RSP7000 and saved your configuration file to a remote server before doing so,
proceed to the section "Downloading (Retrieving) the Configuration File" on page 14. If you
replaced the RSP7000 and did not save the configuration, use the configure command or the setup
command facility to reenter the configuration information. Refer to the appropriate software
documentation for command descriptions and instructions for using them.
An error condition exists if no LEDs go on at power up or after initialization, or if the boot error or
CPU halt LEDs go on and remain on. If this happens, refer to the troubleshooting information in the
Cisco 7000 Hardware Installation and Maintenance or Cisco 7010 Hardware Installation and
Maintenance publication to try to isolate the problem, or contact a service representative for
assistance.
This completes checking the RSP7000 installation
22 Installing the RSP7000 Upgrade Kit in the Cisco 7000 Series Routers
Check the RSP7000 connections to make sure they are secure:
•
The RSP7000 is inserted all the way into the chassis' 7000 RSP slot (see Figure 1 on
page 2 or Figure 2 on page 3), and that both of the captive installation screws are
tightened.
•
The console terminal is turned on and is connected to the console port.
Observe the RSP7000 LEDs. While the system initializes, the yellow boot error LED on
the RSP7000 stays on, then goes off when the boot is complete. As the RSP7000 initializes
each interface processor, the status LEDs on each interface processor go on and off in
irregular sequence.
Verify that the console terminal displays the system banner and startup screen as the system
restarts. The display should look similar to the following:
GS Software (RSP-K), Version 10.3(9), RELEASED SOFTWARE
Copyright (c) 1986-1995 by cisco Systems, Inc.
Compiled Wed 10-May-95
System Bootstrap, Version 5.3(9)
Current date and time is Sat 5-13-1995 21:38:35
Boot date and time is Thur 5-11-1995 15:32:28
[displayed text omitted from this example]
After the system boots the software and initializes the interface processors (approximately
30 seconds for systems with 16 MB of DRAM, and approximately 2 minutes for systems
with 64 MB of DRAM), verify that the RSP7000 LEDs are in the following states:
•
RSP7000 normal LED is on
•
CPU halt LED is off
•
Boot error LED is off
Verify that all the enabled LEDs (on the interface processors) are on.