- ページ 4

屋外ライト Acuity Brands Lighting Holophane Wallpack HLWCP2のPDF インストレーション&メンテナンス・マニュアルをオンラインで閲覧またはダウンロードできます。Acuity Brands Lighting Holophane Wallpack HLWCP2 6 ページ。 Full cutoff led luminaire

HOLOPHANE
 
Figure 3
3" mount
2.2.4 For conduit entry or J-Box mounting, remove the
appropriate threaded plug on the electrical housing
2.2.5 Insert the supply wires or thread conduit through
the hole and secure housing to the wall using fasteners,
not included, that are appropriate for the size and weight
of the luminaire as well as the substrate the luminaire is
being mounted to.
2.2.6 Apply a continuous bead rubber silicon to seal the
back housing to the wall.
2.2.7 Apply a continuous bead rubber silicon to fully seal
any unused conduit entry points.
2.3 Wiring the Luminaire – Standard Luminaire
2.3.1 Using the provided chains and hooks, hang the
heatsink on the electrical housing for temporary support
during wiring.
2.3.2 Check Voltage to ensure the line voltage matches
the voltage range shown in the luminaire description on
the fixture label.
2.3.3 Reconnect any wiring that had been undone when
removing the heatsink from the electrical housing.
2.3.4 Connect the line voltage supply wires to the
luminaire input wires using the pre-installed lever nuts.
2.4 Wiring the Luminaire – Emergency Battery Pack
(EM) Luminaires only
2.4.1 Follow steps 2.3.1 to 2.3.3
2.4.2 Connect the line voltage supply wires to the
luminaire input wires using the pre-installed lever nuts.
For the emergency battery pack, both the switched
(white/red wire from battery) and unswitched
(orange/black wire from battery) lines are run through
surge protection devices. The unswitched line will be
labeled on the surge protection device.
2.4.3 Connect the battery pack inverter (red and white
wires with clear, plastic caps) to enable the battery back-
up
CAUTION: The emergency battery pack must be
allowed to charge for 24 hours prior to testing operation.
The battery will continuously discharge until it is drained
and will begin charging when the luminaire is energized.
CAUTION: Luminaires with an emergency battery pack
cannot be mounted higher than 10.74 ft. from the ground
 
®
Wallpack
LED Luminaire (HLWPC2)
5" mount
4" mount
GR2675
®
Full Cutoff
in order to comply with UL emergency lighting 1-ft candle
criteria
2.5 Wiring the Luminaire – Two Independent Circuit
(2CI) Luminaires only
2.5.1 Follow steps 2.3.1 to 2.3.3
2.5.2 Connect the line voltage supply wires to the
luminaire input wires using the pre-installed lever nuts.
For the 2CI option, there should be 2 identical drivers
present in the luminaire. The driver that is intended to be
powered by the building's inverter has an "unswitched"
label from the factory. The wire color for the unswitched
line will be variable depending on the performance
package chosen.
2.6 Attaching Heatsink to Electrical Housing (Figure
4)
2.6.1 Bring the heatsink close to the electrical housing
and insert the 4 guiding pins on the heatsink into the 4
guiding holes in of the electrical housing
2.6.2 Making sure not to pinch any wires or chains, slide
the heatsink until it makes contact with the electrical
housing.
2.6.3 Tighten the 6 screws to 20-25 in-lbs. to ensure a
watertight seal and a secure connection of the heatsink
to the electrical housing.
FAILURE TO TIGHTEN HOUSING SCREWS COULD
CAUSE LUMINAIRE TO FALL RESULTING IN
INJURY, DEATH OR SERIOUS PROPERTY DAMAGE.
NE PAS SERRER CORRECTEMENT LA VIS DE
RÉGLAGE PEUT PROVOQUER LA CHUTE DE LA
FIXATION ET CAUSER DES BLESSURES,
PROVOQUER LA MORT OU DE SÉRIEUX
DOMMAGES MATÉRIELS.
Figure 4
 
Installation and
Maintenance
Manual
WARNING
AVERTISSEMENT
GR2676
IM‐438‐B