- ページ 14
コントロールユニット ABB 2TLA020054R0400のPDF オリジナル取扱説明書をオンラインで閲覧またはダウンロードできます。ABB 2TLA020054R0400 16 ページ。 Bypassing unit
6
Technical data
Manufacturer
Address
Article number/Ordering data
Power supply
Operating voltage
Current consumption, A1-A2
Bypass connection
Time delay t (in/out)
Voltage supply at normal operation (protection OK)
and 24 VDC supply voltage
General
Protection class
Ambient temperature
Humidity range
Connectors
Mounting
Size
Weight
Colour
Safety / Harmonized Standards
Conformity
IEC/EN 61508-1...7
EN 62061
EN ISO 13849-1
EN 954-1
Certificates
2TLC172131M0201, rev. A
2011-09-20
ABB AB / JOKAB SAFETY
Varlabergsvägen 11
SE-434 39 Kungsbacka
Sweden
Tina 5A: 2TLA020054R0400
24 VDC +10 %, -10 %
No bypass: 10 mA
Bypass using a 5 W indication lamp: 240 mA
Tina 5A can bypass max. 30 Eden/Tina-units or 6 Spot T/R
t < 260 µs
Dynamic input: between 9 and 13 volt (RMS)
Dynamic output: between 9 and 13 volt (RMS)
Information output: ~ 23 VDC
Enclosure: IP40
Connection block: IP20
-10...+55°C
35 to 85 % (with no icing or condensation)
Connection blocks with a total of 8 screw terminals (2 x 4). Max tightening torque 1 Nm.
35 mm DIN rail
120 x 84 x 22.5 (L x W x H)
~ 135 g
Black and beige
European Machinery Directive 2006/42/EC
EN ISO 12100-1:2003, EN ISO 12100-2:2003,
EN 60204-1:2007, EN 954-1:1996, EN ISO 13849-1:2008,
EN 62061:2005, EN 61496-1:2004 + A1:2008
-9
SIL3, PFH
: 4.50*10
d
SIL3
Performance level: Pl e, category 4
Category 4
TÜV Nord
14
www.abb.com/lowvoltage