- ページ 11

換気フード Whirlpool UXT4836AAWのPDF 取扱説明書をオンラインで閲覧またはダウンロードできます。Whirlpool UXT4836AAW 28 ページ。 30" (76.2 cm) and 36" (91.4 cm) range hood

Whirlpool UXT4836AAW 取扱説明書
Fire Hazard
Electrically ground the blower.
Use copper wire.
Connect ground wire to green ground screw in
terminal
box.
Failure to do so can result in death, fire, or
electrical shock.
Direct Wire Installation
1. Connect the white wire of the home power supply cable with
the white wire in the range hood using a UL listed wire
connector.
E
A. White wires
B. Black wires
C. Green ground screw
D. Ground wire
E. UL listed or CSA approved strain relief
F. UL listed wire connector
2. Connect the black wire of the home power supply cable with
the black wire in the range hood using a UL listed wire
connector.
3. Connect ground wire (green or bare) of home power supply
cable to the green ground screw in the terminal box.
4. Tighten strain relief screws.
5. Install the terminal box cover.
6. Reconnect power.
Install 40-watt
(max) type A-15 appliance
light bulbs.
1. Squeeze both sides of the lens cover to remove the tabs from
the slots in the range hood and remove lens cover.
B
A. Light bulb socket
B. Lens cover
C. Lens cover slots
D. Lens cover tabs
2. Screw two 40-watt light bulbs into sockets.
3. Reinstall lens cover by squeezing both sides of the lens cover
and inserting the tabs into the slots in the range hood.
Install Charcoal
filter
For non-vented (recirculating) installations:
Install charcoal filter pad Part Number 4396388 available from
your dealer. See "Range Hood Care" section for installation
instructions.
Check Range Hood Operation
1. Check light operation by turning the light knob.
2. Check operation of fan by turning the fan knob.
3. If the range hood does not operate, check to see whether a
circuit breaker has tripped or a house fuse has blown.
4. NOTE: To get the most efficient use from your new range
hood, read the "Range Hood Use" section.
11