- ページ 13
調理器 Zanussi ZCG560GのPDF ユーザーマニュアルをオンラインで閲覧またはダウンロードできます。Zanussi ZCG560G 20 ページ。 Zanussi zcg560g cooker user manual
Zanussi ZCG560G にも: ユーザーマニュアル (20 ページ)
Gas burners
NORMAL POW-
BURNER
kW
1,00
Auxiliary
burner
1,00
0,85
2,00
Semi-rapid
burner
2,00
1,70
3,00
Rapid burner
3,00
2,60
2,70
Oven
2,50
2,15
Gas Connection
Choose fixed connections or use a flexible pipe in stain-
less steel in compliance with the regulation in force. If you
use flexible metallic pipes, be careful they do not come in
touch with mobile parts or they are not squeezed.
When you install and connect the appliance, obey
the directives:
• SVGW- Gas principles G1: Gas installation
• EKAS- Form. 1942: Liquid gas directive, Part 2
• Cantonal instances regulations (e.g. fire safety regula-
tors)
Flexible nonmetal pipes connection
If it is possible to easily control the connection in its full
area, you can use a flexible pipe. The flexible pipe must be
tightly attached by clamps.
Installation: use the pipe holder. Always engage the gas-
ket. Then continue with the gas connection. The flexible
pipe is prepared for apply when:
www.zanussi.com
REDUCED
ER
POWER
kW
0,35
0,35
0,31
0,43
0,43
0,40
0,72
0,72
0,63
0,90
0,90
0,78
Type of gas
Pressure
mbar
Natural gas
20
G20
Butane G30
50
Propane G31
50
Natural gas
20
G20
Butane G30
50
Propane G31
50
Natural gas
20
G20
Butane G30
50
Propane G31
50
Natural gas
20
G20
Butane G30
50
Propane G31
50
– it can not get hot more than room temperature, higher
than 30°C;
– it is no longer than 1500 mm;
– it shows no throttles;
– it is not subject to traction or torsion;
– it does not get in touch with cutting edges or corners;
– it can be easily examined in order to check its condi-
tion.
The control of preservation of the flexible pipe consists in
checking that:
– it does not show cracks, cuts, marks of burnings on the
two ends and on its full length;
– the material is not hardened, but shows its correct
elasticity;
– the fastening clamps are not rusted;
– expired term is not due.
If one or more defects are visible, do not repair the pipe,
but replace it.
Inj. diameter
Cons.
mm
g/h
0,70
-
0,43
72,71
0,43
60,70
0,96
-
0,60
145,43
0,60
121,40
1,19
-
0,77
181,78
0,77
157,11
1,20
-
0,63
196,33
0,63
162,82
13