9. Service & Maintenance
ATTENTION
When performing any repair or maintenance, the general safety rules and
provisions must be adhered to!
In order to guarantee a troublefree function of the dryer the device should be
cleaned regularly. The following procedure is recommended:
Switch off the dryer
Pull main cable from the socket
Remove filter holder (see 1.1)
Remove filter and clean or organize new one
Remove cover (front/top-panel).
Blow out device cautiously with compressed air. (wear protective goggles!) In
this case, it might ensure that all components are cleaned. (Compressor,
evaporator, condenser, ect.)
mount cover (front/top-panel).
Check hose connector and connected hose
Clean case with moist cloth. Do not use aggressive detergent
Insert new or cleaned filter. Use only original AERIAL-filter for problemfree
working.
Insert filter holder
Put plug into socket
Switch on the dryer
This cleaning is without fail regularly required!
During construction site effort, after every effort or once a week!
10. Trouble shooting
Weist der Entfeuchter einen vermeintlichen Defekt auf, überprüfen Sie bitte
zunächst die folgenden Punkte. Sollte dies keine Abhilfe schaffen, wenden Sie sich
an Ihren Fachberater.
Assign that dehumidifier a putative defect on, please, first check the following points.
If this should provide no relief, please contact your technical consultant.
1)The dehumidifier shows a bad or no drying capacity
- The humidity is lower than 40% r.h. or the temperature in that room is lower than
+3° C. The using of the dryer is uneconomical in the case of these conditions. It is
recommended to disconnect the dryer. Tipp: Put the built-in hygrostat on an
attainable value (e.g. approx. 50%r.F.), with it the dryer punctually may switch off.
- The air filter is soiled. The dryer does not receive air sufficiently. Clean the filter
and/or install a new one. A soiled air filter can in the long run lead to
disadvantages at the dryer. Tipp: Control the filter regularly. Do only use original
air filters!
2) The fan of the dehumidifier does not work, the compressor still turns.
- The unit is in defrost mode. In this case the compressor still runs and the fan does
not run. After some minutes, the unit will start with regular working.
page 13 of 15